The following table shows the results of the Auto Reconnect On and Off settings:
Event
Scanner out of range
Base reset (firmware upgrade or
power cycle)
Scanner reset due to firmware
upgrade
Scanner reset due to instant
charge pack change
Scanner placed in different base
unit

Maximum Link Attempts

The Maximum Link Attempts setting controls the number of times the scanner tries to form a connection with a base.
During the connection setup process, the scanner transmits in order to search for and connect to a base. In order to pre-
vent continuous transmissions that could interfere with other users of the ISM band, the number of attempts to connect is
limited by this setting. After the maximum number of attempts is reached, the scanner will not attempt to reconnect to a
base. Pressing the scanner's button or placing the scanner in the base resets the attempt count and the scanner will again
try to link.
Scan the Maximum Link Attempts bar code, then scan the number of attempts for the setting (from 0-255) from the inside
back cover. Scan Save to save the setting. Default = 0.
Note: When Auto Reconnect Mode is On, setting Maximum Link Attempts to zero will cause the scanner to try to link until
the Power Time-Out Timer setting (see
Attempts has no effect..

Bluetooth/ISM Network Activity Examples

Default values
When the scanner goes out of range, the scanner repeatedly attempts to connect to the base unit. Each attempt consists
of approximately 5 seconds of active time followed by 3 seconds of idle time.
Maximum Link Attempts set to 15
Other values at default settings
When the scanner goes out of range, 15 attempts are made to link to the base unit. Each attempt consists of approximately
5 seconds of active time followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes, the scanner
stops trying to connect to the base.
Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at default settings
Auto Reconnect On
Relink occurs automatically. If maximum
number of link attempts is unsuccessful,
then the scanner must be relinked by
either pressing the scanner's button or
placing the scanner in the base. (See
"Maximum Link Attempts" on page 4-9.)
Scanner behaves as if out of range.
Relink occurs automatically.
Relink occurs automatically.
Relink to new base occurs automatically.
Maximum Link Attempts
page
4-8) expires. When Auto Reconnect Mode is Off, setting Maximum Link
Auto Reconnect Off
The scanner is relinked by pressing
the scanner's button.
No attempt to relink made while base
is powered off. The scanner's button
must be pressed to initiate relinking.
4 - 9