Specifications; Environmental Specifications; Server Specifications - HP ProLiant DL385 G5p Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL385 G5p:
Table of Contents

Advertisement

Specifications

Environmental specifications

Specification
Temperature range*
Operating
Shipping
Storage
Maximum wet bulb
temperature
Relative humidity
(noncondensing)**
Operating
Non-operating
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.

Server specifications

Specification
Dimensions
Height
Depth
Width
Weight (maximum)
Weight (no drives installed)
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Value
10°C to 35°C (50°F to 95°F)
-30°C to 50°C (-22°F to 122°F)
-30°C to 60°C (-22°F to 140°F)
28°C (82.4°F)
10% to 90%
5% to 95%
Value
8.85 cm (3.45 in)
69.20 cm (27.25 in)
44.54 cm (17.54 in)
27.27 kg (60.12 lb)
21.36 kg (47.10 lb)
100 to 132 VAC, 200 to
240 VAC
50 Hz to 60 Hz
6.8 A at 100 VAC
3.4 A at 200 VAC
670 W at 100V AC input
650 W at 200V AC input
2285 at 100V to 120V AC input
2217 at 200V to 240V AC input
Specifications 80