Canon Pixma MP530 Service Manual page 14

Inkjet photo printer
Hide thumbs Also See for Pixma MP530:
Table of Contents

Advertisement

RX
Recording paper jam, or no recording paper
#009
TX
No recording paper at the receiving machine
#012
TX
Redial time-over, but no DT detected
#017
TX
Auto dialing transmission error, or redial time-over
#018
TX
Call failed (no dial registration)
#022
RX
Memory overflow at reception of an image
#037
TX
No color fax function supported in the receiving machine
#085
TX / RX Transmission terminated mid-way by pressing the Stop/Reset button
#099
TX / RX During TX (sending): Memory transmission reservation cancelled
#995
During RX (receiving): Image data received in the memory cleared
(2) Service error codes
Error code TX / RX
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##100
TX / RX Sender's modem speed does not match the receiving machine.
##101
TX
Fallback is not possible.
##102
RX
EOL has not been detected for 5 seconds (or 15 seconds in CBT).
##103
TX
RTN or PIN has been received.
##104
RX
The procedure signal has been expected for 6 seconds, but not received.
##106
RX
Fallback is not available at the sending machine.
##107
TX
After DCS transmission, a signal other than DIS, DTC, FTT, CFR, or CRP has been received, and re-
##109
transmission of the procedure signal has been attempted the specified number of times but failed.
TX / RX Memory error
##111
RX
RTN has been received.
##114
RX
A carrier has not been detected for 5 seconds during image reception.
##200
TX / RX DCN has been received in a method other than the binary procedure.
##201
TX
DTC has been received even when there is no sending data.
##204
TX / RX System error (main program hang-up)
##220
TX / RX An error has occurred in the procedure signal in G3 transmission.
##224
TX / RX The stack pointer has shifted from the RAM area.
##226
RX
The recording area has been locked for 1 minute.
##229
TX
The encoder control unit has malfunctioned.
##232
RX
The decoder control unit has malfunctioned.
##237
RX
The print control unit has malfunctioned.
##238
TX / RX A system error has occurred between the modem and the system control board.
##261
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##280
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##281
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##282
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##283
TX
After TCF transmission, DCN has been received.
##284
TX
After EOP transmission, DCN has been received.
##285
Meaning