Installation

Top Vent Configuration

!
The vent must maintain the required clearance to combustible materials to prevent a fire (see
"Clearances" below). Do not fill air spaces with insulation.
!
The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it's own separate vent system.
Installing the Top Vent Adapter (shipped with the fireplace)
1/4" Nutdriver
Apply a 1/8" thick bead of high-
e
temperature (600° F.) silicone to
the inside of the exhaust vent.
Travis Industries
(for qualified installers only)
Remove the top vent
a
seal plate.
Remove the top vent
b
cover and discard.
Remove the top vent
exhaust cover with
gasket and discard
Remove the top vent
c
convection cover.
Install the top
g
vent seal plate.
1/4" Nutdriver
Install the top
f
vent adapter.
4 0 2 0 8 1 2
7/16" Wrench
d
9 3 5 0 8 1 1 0