Installation
1 0
Facing Requirements
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it
does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Facing Requirements:
Mantel
Minimum Facing
Above Faceplate
Depth
18""
8"
10"
18-1/2"
19"
12"
Bottom of
Faceplate
Base of
Fireplace
Facing Over 1"
Thick
•
If the facing material
is over 1" thick (e.g.
brick, river rock),
install the facing
around the perimeter
of the face. You may
wish to make a facing
support (see the
illustration to the
right). If using an
arch face, you may
wish to order the
optional set-up face:
Arch Set-Up Face
Part # 98500694
NOTE: Artisan faces
vary in size. Use the
face being installed to
create a template.
Travis Industries
Arch Face
Face Size
Discovery, Rosario
Heritage Bay
Salish Bay
Cambridge
FPX Arched or Rect.
1"
Width
Face Sizing
Discovery, Rosario
35-3/4"
Heritage Bay
35-3/8"
Salish Bay
33-1/2"
Cambridge
36-1/4"
FPX Arched or Rect.
34-3/4"
Note: if using a brick hearth, the fireplace will need to be raised to accommodate the 1" gap betwen the
face and the base of the fireplace. For 2-1/2" thick brick this works out to approximately 1-1/2".
4 0 2 0 8 1 2
(for qualified installers only)
Rectangular Face
Width
Height
35-3/4"
26"
35-3/8"
25-5/8"
33-1/2"
26-3/8"
36-1/4"
25-7/8"
34-3/4"
26-1/2"
The brick facing must meet the same requirements
listed in "Facing Requirements" above.
Height
26"
25-5/8"
26-3/8"
25-7/8"
26-1/2"
Center
Line
Arch Faces
Use the optional Arch
Set-Up Face available
from Travis
1"
Industries.
The fireplace requires a concrete
board (or other non-combustible)
extending from the header to the
floor and to the framing members on
both sides. Do not use sheetrock,
plywood or other combustible
material.
Header
Non-combustible Facing
6" Min.
(both sides)
Rectangular Faces
Make a facing support using
2x4's. It should be 1/8" larger
than the finished face. NOTE:
The bottom of the face is 1"
above the base of the fireplace.
9 3 5 0 8 1 1 0