Temperature Sensor Check - Gree Neo GWH09MA-A3DNA3A Installation, Service & Troubleshooting

Ductless system
Hide thumbs Also See for Neo GWH09MA-A3DNA3A:
Table of Contents

Advertisement

Using a glass of ice water, place the sensor into the glass with a digital thermometer. Wait a few minutes for the
reading to stabilize. Compare the readings to the sensor tables in Appendix "A", it the reading are not compara-
ble, replace the sensor. When replacing the sensor, be sure to fasten the sensor securely if it is attached to a tube.
Temp
Temp
(ºC)
(ºF)
0
32.0
1
33.8
2
35.6
3
37.4
4
39.2
5
41.0
6
42.8
7
44.6
8
46.4
9
48.2
Troubleshooting Outdoor Components

Temperature Sensor Check

Resis-
Temp
tance
(ºC)
(kΩ)
49.02
52
46.6
53
44.31
54
42.14
55
40.09
56
38.15
57
36.32
58
34.58
59
32.94
60
31.38
61
Temperature
Sensor
Temp
Resis-
(ºF)
tance
(kΩ)
125.6
4.986
127.4
4.802
129.2
4.625
131.0
4.456
132.8
4.294
134.6
4.139
136.4
3.99
138.2
3.848
140.0
3.711
141.8
3.579
Temp
Temp
Resis-
(ºC)
(ºF)
tance
(kΩ)
104
219.2
0.898
105
221.0
0.873
106
222.8
0.848
107
224.6
0.825
108
226.4
0.802
109
228.2
0.779
110
230.0
0.758
111
231.8
0.737
112
233.6
0.717
113
235.4
0.697
85

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents