Miscellaneous Malfunctions - Gree Neo GWH09MA-A3DNA3A Installation, Service & Troubleshooting

Ductless system
Hide thumbs Also See for Neo GWH09MA-A3DNA3A:
Table of Contents

Advertisement

The fan does not run
when set to run
Compressor runs,
outdoor fan will not
Outdoor fan runs,
compressor will not
run
Troubleshooting

Miscellaneous Malfunctions

Fan capacitor has open circuit or
damaged
Motor overload protector faulty
Motor winding open
Incorrect wiring or bad connection
Fan capacitor has open circuit or
damaged
Motor winding open
Incorrect wiring or bad connection
Faulty compressor
Open or shorted capacitor
Improper voltage
Incorrect wiring or bad connection
Overload protector faulty
Replace capacitor
Replace motor
Replace motor
Repair connection, wire per
schematic
Replace capacitor
Replace motor
Repair connection, wire per
schematic
Replace compressor
Replace capacitor
Check for proper voltage of power
module, replace module if input is
OK and output is incorrect
Repair connection, wire per
schematic
Replace protector if faulty
133

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents