Compressor Windings; Reactor - Gree Neo GWH09MA-A3DNA3A Installation, Service & Troubleshooting

Ductless system
Hide thumbs Also See for Neo GWH09MA-A3DNA3A:
Table of Contents

Advertisement

Compressor Windings

Red, Yellow & Blue Wires
Compressor Winding Resistance Check:
Remove the compressor wires from the AP1 circuit board. The wires red to yellow, yellow to blue & red to blue
should have readings from 2 - 4 ohms. There should be no reading from any wire to chassis ground. If the read-
ings between the windings differ greatly, the windings are bad. If there is a reading from any wire to the chassis,
there is leakage in the windings.
The reactor filters out electrical noise and transient voltage spikes to the control board. There will be a reading of
less than 1 Ω after the wires are removed. There should be no reading from either reactor terminal to ground.
86
Troubleshooting Outdoor Components
Compressor Windings

Reactor

Slightly depress tab for
easy removal

Hide quick links: