Air-to-water Heat Pump All in One Versati
Model
GRS-CQ14PdG/NhH2-E
GRS-CQ16PdG/NhH2-E
Notes
(a) No additional charge of the refrigerant is need when the pipe length is less than 10m, if the pipe length is
longer than 10m, additional charge of the refrigerant is needed according to the table.
(b) Example: If 6kW model is installed at a distance of 20m, (20-10)x16=160g refrigerant should be added.
Rated capacity is based on standard pipe length and maximum allowable length is based on the product
reliability in the operation. Oil trap should be installed every 5-7 meters when the location of outdoor unit is
higher than indoor unit.

9. Remote Air Temperature Sensor

NO
CN8
Pipe size
(Diameter:Φ)
gas
Liquid
5/8"
1/4"
5/8"
1/4"
Front side
Remote Air Temperature Sensor
NO
PCB
Electric box
Length A
Standard
Max.
Standard
5m
15m
5m
15m
Back side
YES
1.5 Meters
Remote Air Environmen t
Temp sensor
15K
CN1
2
26
SPLIT
Elevation B
Additional
refrigerant
Max.
0m
15m
0m
15m
NO
NO
Doors
RT6
AP
TYPE
0g/m
0g/m