Adjustment When Replacing A Part; Okipage6E: 300 Dpi Led Head; Led Head Drive Time Setting; Led Head Luminous Energy - Oki OKIPAGE 6e Service Manual

Hide thumbs Also See for OKIPAGE 6e:
Table of Contents

Advertisement

4.3

Adjustment When Replacing a Part

4.3.1

OKIPAGE6e: 300 dpi LED head

The following table lists parts that require adjustment after replacement.
Parts
LED head
Image drum unit
Control P.C.B.

LED Head Drive Time Setting

Caution: Do not change the LED head drive time when the luminous energy indicated on
The LED head drive time is set in the LED Head Marking No. on the Engine Menu of the
Maintenance Utility. Input the value printed on the serial No. label on the LED head. The
last 3 digits indicates the luminous energy of the LED head. (See Fig. 4-2.)

LED Head Luminous Energy

Adjustments
LED head drive time
LED head width
Type of the LED head
Drum counter reset (Refer to the user's manual for details.)
Upload/Download EEPROM data
the new LED head is the same as that of the old LED head.
Required Adjustment
The last 3 digits indicates the
luminous energy of the LED head.
Luminous energy indications
070
|
314
4 - 4
Service Manual, P/N 59276401