Fan Error (Error 70) - Oki OKIPAGE 6e Service Manual

Hide thumbs Also See for OKIPAGE 6e:
Table of Contents

Advertisement

Fan Error (ERROR 70)

5
• Is the fan rotating?
• Yes
• No
Is connector CN1 on the Main Control PCB being connected?
• No
• Yes
Replace the fan or Main Control PCB (check coil resistance of the fan, See 7.3).
Troubleshooting
Replace the Main Control PCB.
Connect connector CN1.