Connections And Control Devices; Water Connection - ESAB Aristo F 300 Instruction Manual

Hide thumbs Also See for Aristo F 300:
Table of Contents

Advertisement

GB
5.1

Connections and control devices

1
Control panel,
(see separate instruction manual)
2
Connection for remote control unit
3
Connection BLUE, with ELP* for coolant to
the welding gun
4
Connection RED, for coolant from welding
gun
5
Connection for welding gun
NOTE! Display (digital instrument) and coolant connections only available on certain models.
* ELP = ESAB Logic Pump, see point 5.2.
5.2

Water connection

The wire feed unit with water connection is equipped with a detection system ELP
(ESAB Logic Pump) which checks that the water hoses are connected. When
connecting a water-cooled welding gun, the water pump starts.
Detection only works with power sources that are equipped with ELP.
bm52ea
6
Connection for shielding gas
7
Connection for control cable from power
source or cooling unit
8
Connection for welding current from power
source. (OKC)
9
Connection BLUE for coolant from cooling
unit
10
Connection RED for coolant to cooling unit
- 10 -