IP address and the facility to be used.
To receive log messages from the Parani-MSP1000, the SYSLOG server must be configured as
"remote reception allowed". If there is a firewall between the Parani-MSP1000 and the SYSLOG
server, there must be a rule that allows all outgoing and incoming UDP packets to travel across
the firewall.
The Parani-MSP1000 supports SYSLOG facilities from local0 to local7. The user can employ
these facilities to save messages from the Parani-MSP1000 separately in the SYSLOG server.
Reduce system log (Time to reduce the log data ) to (system log size)
The system log should be reduced because the internal memory for system log is limited. The
Parani-MSP1000 has a 16 Megabytes memory for system log and port log. If the internal memory
is full, the system log will not be recorded anymore.
Every month
Every week
Every day
Every hour
Table 8-1 The time to Reduce logged data
First day of every month 00:00:00 AM
Every Sunday 00:00:00 AM
Every day 00:00:00 AM
Every hour 0 minute 0 second exactly
Figure 8-2 System logging configuration