Periodic connection
When the network service mode is client, the Parani-MSP1000 attempts to create an outgoing
connection with this interval. If the periodic connection is zero, it means that the Parani -MSP1000
never initiates connection when there is no data received from SPP.
When Bluetooth connection is established: Initiate connection or Do nothing
If the "Initiate connection" is selected, the Parani-MSP1000 attempts to connect to remote host
immediately when Bluetooth connection is established. However, If the "Do nothing" is selected,
the Parani- MSP1000 waits until data is arrived from SPP.
Vertex port
It is a TCP port to communicate with Bluetooth devices. The user can select one of some vertex
ports.

5.5.7. Logging (Custom mode only)

If the Pairing mode (not port pairing mode) is "Custom", the logging functionality is available. The
configurable parameters are as follows:
Activation
When this is "enable," the Parani- MSP1000 starts logging the data sent/received to/from the SPP
connection.
Log location
The data is able to be logged to memory or CF memory (when a CF memory is plugged). The
logged data is saved to a file whose name is "portlogs/the_BD_address.log"
Data stream to be logged
Logging mode
If the data is composed of only readable text (not including binary codes), select "Text." If the data
includes binary codes, select "Pure binary" or "Readable binary." When the logging mode is
"Readable binary," the Parani- MSP1000 converts the binary data to text data and save it.
Reduce the port log file [ Time to reduce the log data ] to [ Log buffer size ]
The system log should be reduced because the internal memory for system log is limited. The
Parani-MSP1000 has a 16 Megabytes memory for system log and port log. If the internal memory
is full, the system log will not be recorded anymore.
Every month
Every week
Every day
Every hour
Table 5-1 The time to Reduce logged data
First day of every month 00:00:00 AM
Every Sunday 00:00:00 AM
Every day 00:00:00 AM
Every hour 0 minute 0 second exactly