Set The Governor; A X Label; Pressure Testing; Affix Label - Falcon Professional + Kitchener 110 User Manual

Installation instructions
Table of Contents

Advertisement

WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have nished.
Fig.8-4
ArtNo.103-0006 - Maxitrol cap & converter
Fig.8-5
ArtNo.102-0007 - Maxitrol converter device positions
Nut
Snap-in converter device

Set the Governor

Unscrew the governor's brass top. In the base of the brass top
is a plastic snap-in converter device (Fig.8-4). To convert the
governor, snap the device out of the top and re t it the other
way round. The snap-in converter device is marked to show
the gas for which it is set (Fig.8-5).
Make sure the device is secure in the top cap and re t the cap
to the governor.

Pressure Testing

The pressure test point is accessible on the inlet pipe at the
rear. Remove the test nipple screw and t a pressure gauge to
the test point. Turn on and light two of the hotplate burners.
For Propane X cookers the pressure should be 2.54 kPa.
Check the appliance is gas sound.
n
n
Check operation of all the burners.
n
n

Affix Label

Stick the appropriate gas label over the natural gas part of the
appliance data label.