Detaching And Refitting The High Voltage Pwb - Kyocera FS-C5350DN Service Manual

Hide thumbs Also See for FS-C5350DN:
Table of Contents

Advertisement

2K8

(4) Detaching and refitting the high voltage PWB

Procedure
1. Remove the all drum units (See page 1-5-
14).
2. Remove the all developing units (See page
1-5-12).
3. Remove the engine PWB (See page 1-5-
29).
4. Remove the screw and then remove the HV
terminal assembly K.
5. Remove the screw and then remove the
inner cover.
6. Remove the three HV bracket C assem-
blies.
1-5-34
Inner cover
HV bracket
Screw
C assembly
HV terminal assembly K
Figure 1-5-48
HV bracket
C assembly
HV bracket
C assembly
Figure 1-5-49
Screw

Hide quick links: