Kyocera FS-C5350DN Service Manual page 164

Hide thumbs Also See for FS-C5350DN:
Table of Contents

Advertisement

2K8
Connector
Pin
YC31
A1
VDOMP
Connected
A2
VDOMN
to the main
A3
VDOYP
PWB
A4
VDOYN
A5
GND
A6
PDMN
A7
PDYN
A8
GND
A9
FPDATA
A10
FPDIR
A11
+3.3V1
A12
+3.3V1
A13
SO
A14
SDIR
A15
EGIRN
A16
+5V1
A17
+5V1
A18
+5V1
A19
RESETN
A20
GND
B1
VDOCP
B2
VDOCN
B3
VDOCP
B4
VDOCN
B5
GND
B6
PDCN
B7
PDKN
B8
GND
B9
N.C.
B10
FPCLK
B11
FPRSTN
B12
+3.3V1
B13
SI
B14
SCLN
B15
SBSY
B16
VSYNC
B17
EEDAT
B18
EECLK
B19
GND
B20
GND
YC32
1
GND
Connected
2
FPCLK
to the opera-
3
FPDIR
tion panel
4
FPDATA
PWB
5
+3.3V1
6
FPRSTN
7
+5V
2-3-8
Signal
I/O
I
LVDS
I
LVDS
I
LVDS
I
LVDS
-
-
O
0/3.3 V DC (pulse) Horizontal synchronization signal
O
0/3.3 V DC (pulse) Horizontal synchronization signal
-
-
I/O
0/3.3 V DC
I
0/3.3 V DC
O
3.3 V DC
O
3.3 V DC
O
0/3.3 V DC (pulse) Main PWB serial communication data signal
O
0/3.3 V DC
O
0/3.3 V DC
O
5 V DC
O
5 V DC
O
5 V DC
O
0/3.3 V DC
-
-
I
LVDS
I
LVDS
I
LVDS
I
LVDS
-
-
O
0/3.3 V DC (pulse) Horizontal synchronization signal
O
0/3.3 V DC (pulse) Horizontal synchronization signal
-
-
-
-
I
0/3.3 V DC
I
0/3.3 V DC
O
3.3 V DC
O
0/3.3 V DC (pulse) Main PWB serial communication data signal
O
0/3.3 V DC (pulse) Main PWB clock signal
O
0/3.3 V DC
O
0/3.3 V DC
I/O
0/3.3 V DC (pulse) EEPROM data signal
O
0/3.3 V DC (pulse) EEPROM clock signal
-
-
-
-
-
-
O
0/3.3 V DC (pulse) Operation panel PWB clock signal
O
0/3.3 V DC
I/O
0/3.3 V DC
O
3.3 V DC
O
0/3.3 V DC
O
5 V DC
Voltage
APC PWB M video data signal (+)
APC PWB M video data signal (-)
APC PWB Y video data signal (+)
APC PWB Y video data signal (-)
Ground
Ground
Operation panel PWB data signal
Operation panel PWB communication direct signal
3.3 V DC power source
3.3 V DC power source
Main PWB communication direction signal
Engine interrupt signal
5 V DC power source
5 V DC power source
5 V DC power source
Main PWB reset signal
Ground
APC PWB C video data signal (+)
APC PWB C video data signal (-)
APC PWB K video data signal (+)
APC PWB K video data signal (-)
Ground
Ground
Not used
Operation panel PWB clock signal
Operation panel reset signal
3.3 V DC power source
Main PWB busy signal
PD mask control signal
Ground
Ground
Ground
Operation panel PWB communication direct signal
Operation panel PWB data signal
3.3 V DC power source
Operation panel reset signal
5 V DC power source