Kyocera FS-C5350DN Service Manual page 161

Hide thumbs Also See for FS-C5350DN:
Table of Contents

Advertisement

Connector
Pin
YC18
1
STMBN
Connected
2
STMAN
to the drum
3
STMB
motor M/C/
4
STMA
Y/K
5
STCBN
6
STCAN
7
STCB
8
STCA
9
STYBN
10
STYAN
11
STYB
12
STYA
13
STKBN
14
STKAN
15
STKB
16
STKA
YC19
1
HEATREM
Connected
2
N.C.
to the power
3
ZCROSS
source PWB
4
SLEEPN
5
+24V3
6
GND
7
GND
8
GND
9
GND
10
+24V1
11
+24V1
12
+24V1
13
+24V1
YC20
1
+3.3V2
Connected
2
FTHERM
to the paper
3
PDIRN
exit PWB
4
EXITPAP
5
GND
6
FDFUL
7
FEEDOPN
8
FUFANDRN
9
+24V1
10
DUREVDRN
YC21
1
+3.3V2
Connected
2
GND
to the
3
DUREGPAP
duplex con-
4
+3.3V2
veying sen-
5
GND
sor and MP
6
MPHANDS
tray sensor
YC22
1
+24V3
Connected
2
TNMKDRN
to the toner
motor K
Signal
I/O
O
0/24 V DC (pulse) Drum motor M drive control signal (_B)
O
0/24 V DC (pulse) Drum motor M drive control signal (_A)
O
0/24 V DC (pulse) Drum motor M drive control signal (B)
O
0/24 V DC (pulse) Drum motor M drive control signal (A)
O
0/24 V DC (pulse) Drum motor C drive control signal (_B)
O
0/24 V DC (pulse) Drum motor C drive control signal (_A)
O
0/24 V DC (pulse) Drum motor C drive control signal (B)
O
0/24 V DC (pulse) Drum motor C drive control signal (A)
O
0/24 V DC (pulse) Drum motor Y drive control signal (_B)
O
0/24 V DC (pulse) Drum motor Y drive control signal (_A)
O
0/24 V DC (pulse) Drum motor Y drive control signal (B)
O
0/24 V DC (pulse) Drum motor Y drive control signal (A)
O
0/24 V DC (pulse) Drum motor K drive control signal (_B)
O
0/24 V DC (pulse) Drum motor K drive control signal (_A)
O
0/24 V DC (pulse) Drum motor K drive control signal (B)
O
0/24 V DC (pulse) Drum motor K drive control signal (A)
O
24 V DC
-
-
I
0/3.3 V DC (pulse) Zero-cross signal
O
0/24 V DC
O
24 V DC
-
-
-
-
-
-
-
-
I
24 V DC
i
24 V DC
I
24 V DC
I
24 V DC
O
3.3 V DC
I
Analog
I
0/3.3 V DC
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
O
0/12/24 V DC
O
24 V DC
O
0/24 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
24 V DC
O
0/24 V DC
Voltage
Fuser heater lamp: On/Off
Not used
Sleep mode signal: On/Off
24 V DC power source
Ground
Ground
Ground
Ground
24 V DC power source
24 V DC power source
24 V DC power source
24 V DC power source
3.3 V DC power source
Fuser thermistor detection voltage
Envelope switch: On/Off
Paper exit sensor: On/Off
Ground
Paper full sensor: On/Off
Front cover open/close switch: On/Off
Fuser fan motor 1: Full speed/Half speed/Off
24 V DC power source
Duplex solenoid: On/Off
3.3 V DC power source
Ground
Duplex conveying sensor: On/Off
3.3 V DC power source
Ground
MP tray sensor: On/Off
24 V DC power source
Toner motor K: On/Off
Description
2K8
2-3-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecosys p6030cdn

Table of Contents