4000 Series Vandal Resistant Range
Art. 4212V - 4212RV
DATE
Set the date in the call panel.
Modify routine
• press "2" to enter the date menu;
• press "2" to enter edit mode;
• first field will be day when in EU format or month when in US format. All fields are two digits. After entering the two digit number
it will automatically advance to the next field;
• after setting the last parameter time will be saved.
DAY
Set the day of the week.
Modify routine
• press "3" to enter edit mode;
• in edit mode, press "3" repeatedly to scroll through the days;
• press
to save or
to exit edit mode without saving.
TRADE ENABLE
Enables the trade facility working in conjunctions with the trade start and trade end time band and the TRD connection terminal.
When the TRD connection is shorted to 0V and the time is within the trade time band setting it is possible for a user to type in the
trade code to open the door.
Modify routine
• press "3" to enter the trade menu;
• press "1" to enter edit mode;
• press "1" to enable or disable the facility;
• press
to save or
to exit edit mode without saving.
TRADE START - TRADE END
The beginning and end times of the trade time band.
Modify routine
• press "3" to enter the trade menu;
• press "2" or "3" to enter edit mode;
• enter the hour, minutes and seconds (all fields are composed of two digits). After entering two digits it will automatically advance
to the next field. FORMAT is 12 hour then then you will be able to enter AM or PM after the seconds field.
• After setting the last parameter the time will be saved.

RELAY TIME

This parameter specifies how long the relay remains energised when the activated.
Modify routine
• press "4" to enter edit mode;
• edit relay time: it must be between "1" and "255";
• press
to save or
to delete characters or exit edit mode without saving.
SPEECH TIME
This parameter specifies the maximum speak duration. From 1 to 255 seconds".
Modify routine
• press "5" to enter edit mode;
• edit relay time: it must be between "1" and "255";
• press
to save or
to delete characters or exit edit mode without saving.