4000 Series Vandal Resistant Range
Art. 4212V - 4212RV

SYSTEM SETTINGS

System par. menu Parameter Name
1: Language
Language
2: ID
ID
3: Master
Master

4: Panel mode

Panel mode

Security Level

Mode
Enable Direct Call
Proximity Access Mode
LANGUAGE
Languages supported are: English, Italian, Spanish, Portuguese, French, German, Czech, Croatian, Danish, Polish and Slovenian.
Only user messages change language, the programming menu's are always in English.
Modify routine
• press "1" to enter into edit mode;
• press "1" repeatedly to scroll through the available languages;
• press
to save or
to exit edit mode without saving.
ID
The panel ID came be from 1 to 15. Each panel on a system should have a unique ID.
Modify routine
• press "2" to enter into edit mode;
• Enter the panel ID from 1 to 15;
• press
to save or
to delete characters or exit edit mode without saving.
MASTER
Specifies if the panel is a master or a slave. On each bus there should only be one master, all other panels on that bus should be slaves.
Modify routine
• press "3" to enter into edit mode;
• press "3" to enable or disable;
• press
to save or
to exit edit mode without saving.
PANEL MODE
Specifies if the system includes the 2206N bus exchange devices or not and if the panel is a main panel or a local panel. If there are no
2206N devices on the system then this setting should be LOCAL. If there are 2206N devices on the system and this panel is a main en-
trance calling all apartments then this setting should be MAIN. If the panel is a block entrance panel then this setting should be LOCAL.
Modify routine
• press "4" to enter into edit mode;
• press "4" to switch from LOCAL to MAIN and viceversa;
• press
to save or
to exit edit mode without saving.
SECURITY LEVEL
Art. 4212 can work in two different security modes: Fob or Code and Fob + Code.
In Fob or Code, key and code are linked only with user. Insertion of enabled code or passing a key over the reader will open the door.
In Fob + Code, key and code are linked together. Single code is linked with single key.A user must enter a code and present a key to
open the door. Parameter can be changed only through PC programming routine.
Art. 4212V-4212RV - Installation instructions
Audio/video digital front panel
Programming method
By panel and PC software
By panel and PC software
By panel and PC software
By panel and PC software
Only by PC software
Only by PC software
Only by PC software
Only by PC software
Programming
Permission
Only Engineer
Only Engineer
Only Engineer
Only Engineer
/
/
/
/
13
Default value
English
1
Enabled
Local
Fob or Code
Compatibility mode
Disabled
Stand alone mode
66250203-EN - V0.3 - 10/07/15