Pcie Flash Modules (Pfm); Batteries; Power Supply Units; Table 6.3 Mnt Port/Rmt Port/Fst Port Specifications - Fujitsu ETERNUS DX500 S3 Overview

Disk storage system
Hide thumbs Also See for ETERNUS DX500 S3:
Table of Contents

Advertisement

Chapter 6
Hardware Configurations
6.1
Controller Enclosure
MNT Port/RMT Port/FST Port
The MNT port is used for operation management, the RMT port is used for the remote support function, and
the FST port is used for maintenance.
The specifications for the MNT port, the RMT port, and the FST port are provided below.

Table 6.3 MNT Port/RMT Port/FST Port Specifications

Interface
Ethernet (1000Base-T/
100Base-TX/10Base-T)
PWC Ports
The PWC port is used to connect a power synchronized unit to perform power synchronization.
The PWC port specifications are shown below.

Table 6.4 PWC Port Specifications

Interface
RS232C
6.1.2

PCIe Flash Modules (PFM)

The read cache capacity significantly increases when Extreme Cache is used. PCIe Flash Modules (PFM) are
installed to operate Extreme Cache.
1.4TB (700GB PFM ´ 2) and 2.8TB (1.4TB PFM ´ 2) PFM capacity options are available for Extreme Cache.
Two PFMs are installed in each controller. The maximum capacity for each controller is 2.8TB.
PFMs can be added during system operation. When an error occurs, a replacement can be made while the
system is running.
6.1.3

Batteries

Three batteries are installed in the controller enclosure as backup power supply sources.
If one of the three batteries fails, the failed battery can be replaced while the system is running.
The batteries are charged from an external power source while the ETERNUS DX is running normally. If a
power failure is detected, the data in the cache memory is saved to the BUD in the controller by using battery
power. There is no limit to the post-failure data retention time.
6.1.4

Power Supply Units

The power supply unit transforms input AC power from a power socket to DC power and supplies power to
each component. A controller enclosure has two power supply units. Each power supply unit contains fans.
If one of the power supply units fails, the failed unit can be replaced while the system is running.
Transfer rate (max.)
1Gbit/s
Connector type
PWC
FUJITSU Storage ETERNUS DX500 S3/DX600 S3 Disk storage system Overview
Copyright 2015 FUJITSU LIMITED
Connector type
RJ-45
74
Number of ports for each
controller
1 (MNT)
1 (RMT)
1 (FST)
Number of ports for each controller
1
P3AM-7702-14ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx600 s3

Table of Contents