Chapter 3
Basic Functions
3.6
Operation Management
3.6.3

Performance Information Management

The ETERNUS DX supports a function that collects and displays the performance data of the storage system
via ETERNUS Web GUI or ETERNUS CLI. The collected performance information shows the operation status and
load status of the ETERNUS DX and can be used to optimize the system configuration.
Performance information that can be collected includes host I/O information (IOPS values, throughput val-
ues, response time, cache hit rate), QoS information (IOPS values, throughput values, delay time), and the
usage information of CMs (CPUs) and drives.
ETERNUS SF Storage Cruiser can be used to easily understand the operation status and load status of the
ETERNUS DX by graphically displaying the collected information on the GUI. An administrator can also use
ETERNUS SF Storage Cruiser to monitor the performance threshold and specify how long performance infor-
mation is retained.
3.6.4

Device Time Synchronization

The ETERNUS DX has a clock function and manages time information of date/time and the time zone (the
region in which the ETERNUS DX is installed). This time information is used for internal logs and for functions
such as Eco-mode, remote copy, and remote support.
The automatic time correction by the Network Time Protocol (NTP) is recommended to synchronize time in
the whole system.
When using the NTP, specify the NTP server or the SNTP server. The time correction mode is Step mode (im-
mediate correction). The time is regularly corrected every three hours once the NTP is set.

Figure 3.17 Device Time Synchronization

NTP server
NTP
Date and Time
Time Zone
Daylight Saving Time
ETERNUS DX
FUJITSU Storage ETERNUS DX500 S3/DX600 S3 Disk storage system Overview
Copyright 2015 FUJITSU LIMITED
yyyy
mm
dd
xx:xx:xx
GMT
+ 09.00
49
P3AM-7702-14ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx600 s3

Table of Contents