Figure 6-46. Port Packet Error Statistics table
Select the desired device in the Switch field, the desired setting
in the Ports field, and the desired increment setting in the
Update Interval field: 5 sec, 15 sec, 30 sec, 1 min, or Suspend.
The statistic counters displayed are defined as follows:
♦ Speed If the link is up, the speed and duplex status will be
displayed; if the link is down "-" will be displayed.
♦ CRC Error
integrity check.
♦ Oversize The number of good frames with length greater
than 1536 bytes and therefore are greater than the
maximum legal length.
♦ Bad Fragment
bytes with either bad framing or an invalid CRC. These
are normally the result of collisions.
Using the Console Interface
Stackable NWay Ethernet Switch User's Guide
The number of frames that fail the CRC
The number of packets less than 64
121