Full Reline With Outside Air, Vertical - Quadra-Fire MTVERNINSAE-MBK Owner's Manual

Installation and operation mt vernon pellet insert advanced energy (ae)
Hide thumbs Also See for MTVERNINSAE-MBK:
Table of Contents

Advertisement

Mt. Vernon Pellet Insert (AE)
B. Full Reline With Outside Air - Vertical
NOTE: Check clearances carefully for this type of instal-
lation to ensure adequate room for outside air venting.
NOTE: In Canada this fi replace insert must be installed
with a continuous chimney liner of 6 inch (152mm) diam-
eter extending from the fi replace insert to the top of the
chimney. The chimney liner must conform to the Class
3 requirments of CAN/ULC-S635, Standard for Lining
Systems for Extising Masonry or Factory-Built Chimneys
and Vents, or CAN/ULC-S640, Standard for Lining Sys-
tems for New Masonry Chimneys.
Page 18
NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insula-
tion such as mineral wool or
ceramic.
Do not use high temperature caulk-
ing materials to seal any edge to
prevent furture serviceability.
Figure 18.1
NOTE: In Canada only a full reline is allowed per ULC
S628, ORD ULC C1482-M1990.
305mm min.
above
305mm min.
below
Chimney Top
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult local building, fi re offi cials or authorities having
jurisdiction about restrictions, installation inspection, and
permits.
7036-135G
Outside Air
Termination
at
(Vertical)
CAUTION
November 22, 2011