Quadra-Fire MTVERNINSAE-PMH Installation Manual
Quadra-Fire MTVERNINSAE-PMH Installation Manual

Quadra-Fire MTVERNINSAE-PMH Installation Manual

Hide thumbs Also See for MTVERNINSAE-PMH:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
MT VERNON PELLET INSERT
ADVANCED ENERGY (AE)
Model(s):
MTVERNINSAE-MBK
MTVERNINSAE-PMH
MTVERNINSAE-CSB
CAUTION
Tested and approved for wood pellets, shelled fi eld
corn, wheat and black oil sunfl ower seeds. Burning of
any other type of fuel voids your warranty.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and na-
tional codes and regulations.
• Consult local building, fi re offi cials or authorities having juris-
diction about restrictions, installation inspection, and permits.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
Portland
Tested and
O-T L
Listed by
Oregon USA
US
C
OMNI-Test Laboratories, Inc.
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other fl ammable
materials away.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafi re.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez www.quadrafi re.com
7036-188E
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
NOTE
May 5, 2015

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire MTVERNINSAE-PMH

  • Page 1 • Do not store or use gasoline or other fl am- MTVERNINSAE-MBK mable vapors and liquids in the vicinity of this or any other appliance. MTVERNINSAE-PMH • Do not overfi re - If heater or chimney con- MTVERNINSAE-CSB nector glows, you are overfi ring. Overfi ring will void your warranty.
  • Page 2: Table Of Contents

    MT VERNON AE INSERT Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided may result in death or serious injury. •...
  • Page 3: Important Safety Information

    E1509-04, ULC S628-93, (UM) 84-HUD and ULC/ORD- C-1482-M1990. Fire Risk. The Quadra-Fire Mt. Vernon AE Pellet Insert meets the U.S. Hearth & Home Technologies disclaims any Environmental Protection Agency’s emission limits for pellet responsibility for, and the warranty will be inserts sold after May 15, 2015.
  • Page 4: Getting Started

    MT VERNON AE INSERT Install Guide Getting Started A. Design, Installation & Location Considerations Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: 1. Appliance Location • Windows NOTICE: Check building codes prior to installation. •...
  • Page 5: Thermostat Wall Control Location

    MT VERNON AE INSERT B. Thermostat Wall Control Location D. Inspect Appliance and Components The thermostat wall control’s location will have some affect • Open the appliance and remove all the parts and articles on the appliance’s operation. packed inside the Component Pack. Inspect all the parts and glass for shipping damage.
  • Page 6: Install Checklist

    Dealer/ Distributor Phone #: Serial #: Model (circle one): MTVERNINSAE-MBK MTVERNINSAE-PMH MTVERNINSAE-CSB WARNING! Risk of Fire or Explosion! Failure to install fi replace according to these instructions can lead to a fi re or explosion. Appliance Install IF NO, WHY? Verifi...
  • Page 7: Dimensions And Clearances

    MT VERNON AE INSERT Dimensions and Clearances A. Appliance Dimensions 32 in. (812mm) 23-7/8 in. 8-1/8 in. (606mm) (206mm) 2-3/8 in. 15 in. (59mm) (382mm) 29-3/4 in. (756mm) 23-7/8 in. (605mm) 13-1/8 in. (333mm) 26-1/4 in. 28-1/8 in. (667mm) (714mm) Figure 7.1 - Top View Figure 7.2 - Side View 36-5/8 in.
  • Page 8: Clearances To Combustibles (Ul And Ulc)

    MT VERNON AE INSERT B. Clearances to Combustibles (UL and ULC) Built-in Unit - Rear Vent 0 inch Clearance To Exposed Section And Face Trim Figure 8.1 Location Confi guration Inches Millimeters Top of Hopper Top or Rent Vent Side of Outside Skin Top or Rear Vent Back of Hopper Top Vent...
  • Page 9: Masonry And Zero Clearance Fireplaces

    MT VERNON AE INSERT Built-In Vertical E. Minimum Opening for Masonry & Zero Clearance Fireplaces Figure 9.3 Location Inches Millimeters Figure 9.1 Rear Width C. Masonry and Zero Clearance Fireplaces Depth Height 23-7/8 Front Width Face Mantel Trim F. Mantel Projections Figure 9.2 Location Inches...
  • Page 10: Removing Metal Floor Of Factory-Built Firebox

    MT VERNON AE INSERT G. Installation into a Factory-Built Fireplace The following is only one example as there are many differ- ent models of factory-built fi replaces. The following modifi cations are permissible: NOTE: This example is for reference only. Any modifi ca- •...
  • Page 11: Prefabricated Metal Chimney

    MT VERNON AE INSERT I. Prefabricated Metal Chimney Example Removal of Factory-Built Fireplace Cont. The chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements: • Must be minimum 6 inch (152mm) inside diameter of Keep sharp edge of high temperature chimney listed to UL 103 HT (2100 metal floor away from...
  • Page 12: Vent Information

    MT VERNON AE INSERT Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Figure 12.1 Termination Cap Air Supply Inlet Restricted Area Gas Meter All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 13: Avoiding Smoke And Odors

    MT VERNON AE INSERT B. Avoiding Smoke and Odors Vent Confi gurations To reduce probability of reverse drafting during shut-down Negative Pressure, Shut-Down and Electrical Power conditions Hearth & Home Technologies strongly recom- Failure mends: To reduce the probability of back-drafting or burn-back in •...
  • Page 14: Negative Pressure

    Avoid installing the appliance near doors, walkways or to 6 inch (76-152mm) Top Vent Offset Adapter, use Listed small isolated spaces double wall fl ue connector. A Quadra-Fire Outside Air Kit must be used with manufactured home installations. • Recessed lighting should be a “sealed can” design 3.
  • Page 15: Equivalent Feet Of Pipe

    MT VERNON AE INSERT F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet Vent surfaces get HOT, can cause burns if of pipe which is a method used to determine pellet vent size. touched.
  • Page 16: Venting Systems

    MT VERNON AE INSERT Venting Systems A. Full Reline With Outside Air - Horizontal WARNING Fire Risk. CAUTION Inspection of Chimney: • Masonry chimney must be in good condition. Never draw outside combustion air from: • Meets minimum standard of NFPA 211 •...
  • Page 17: Full Reline With Outside Air - Vertical

    MT VERNON AE INSERT B. Full Reline With Outside Air - Vertical NOTE: Check clearances carefully for this type of instal- NOTE: In Canada only a full reline is allowed per ULC lation to ensure adequate room for outside air venting. S628, ORD ULC C1482-M1990.
  • Page 18: Appliance Set-Up

    MT VERNON AE INSERT Appliance Set-Up A. Leveling System B. Outside Air Kit Instructions Included in Kit: 2 wire ties, 1 collar assembly, The leveling bolts are located on the sides of the appliance, 1 termination cap assembly, 1 trim ring, fasteners. front and rear.
  • Page 19: Hearth Support

    MT VERNON AE INSERT 7. Place the assembled hearth support under the insert. C. Hearth Support Lower the leveling bolts if necessary to keep the insert level. Included in Kit: (1) bottom, (1) trim front, (2) trim sides, (2) trim extensions 8.
  • Page 20: Surround And Trim Set - Cast

    MT VERNON AE INSERT F. Surround & Trim Set, Basic E. Surround and Trim Set - Cast Included in Surround Kit: (2) side panels, left and right; Included in Surround & Trim Kit: (2) corner brackets and set (1) panel top; (1) fastener package. screws;...
  • Page 21: Optional Log Set Placement Instructions

    MT VERNON AE INSERT G. Optional Log Set Placement Instructions The center 3 screws are for the wall control thermostat wires and the 2 outer screws are mounting screw and 2 PIECE LOG SET INSTALLATION should not have wires attached to them. 1.
  • Page 22: Mobile Home Installation

    MT VERNON AE INSERT Mobile Home Installation CAUTION You must use a Quadra-Fire Outside Air Kit for installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE An outside air inlet must be provided for the combustion...
  • Page 23: Accessory List

    MT VERNON AE INSERT Accessory List MT VERNON INSERT-AE Service Parts Beginning Manufacturing Date: Sept. 2006 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Stocked Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 24: Contact Information

    Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL...

This manual is also suitable for:

Mtverninsae-mbkMtverninsae-csb

Table of Contents