INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
MT. VERNON PELLET STOVE
ADVANCED ENERGY (AE)
Model(s):
MTVERNON-AE-CSB
MTVERNON-AE-MBK
MTVERNON-AE-PBK
MTVERNON-AE-PDB
MTVERNON-AE-PFT
MTVERNON-AE-PMH
CAUTION
Tested and approved for wood pellets, shelled field
corn, wheat and black oil sunflower seeds. Burning of
any other type of fuel voids your warranty.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and na-
tional codes and regulations.
• Consult local building, fire officials or authorities having juris-
diction about restrictions, installation inspection, and permits.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
Tested and
O-T L
Portland
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
061-S-68-6
If the information in these instruc-
tions is not followed exactly, a
fire may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfire - If heater or chimney con-
nector glows, you are overfiring. Overfiring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specified. Failure to
comply may cause house fire.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fireplace.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other flammable
materials away.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafire.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez www.quadrafire.com
7034-277B
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
NOTE
May 2, 2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTVERNON-AE-CSB and is the answer not in the manual?

Questions and answers

Summary of Contents for Quadra-Fire MTVERNON-AE-CSB

  • Page 1 If the information in these instruc- MT. VERNON PELLET STOVE tions is not followed exactly, a fire may result causing property ADVANCED ENERGY (AE) damage, personal injury, or death. Model(s): • Do not store or use gasoline or other flam- MTVERNON-AE-CSB mable vapors and liquids in the vicinity of MTVERNON-AE-MBK this or any other appliance. MTVERNON-AE-PBK • Do not overfire - If heater or chimney con- nector glows, you are overfiring. Overfiring MTVERNON-AE-PDB will void your warranty.
  • Page 2: Table Of Contents

    MT. VERNON AE Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided may result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. • NOTICE: Indicates practices which may cause damage to the appliance or to property. TABLE OF CONTENTS Important Safety Information .....3 Venting Systems .......13 A. Appliance Certification ............3 A. Alcove 13 B. BTU & Efficiency Specifications........3 B.
  • Page 3: Important Safety Information

    Pellets, Shelled Field Corn, For assistance or additional information, consult a qualified Wheat and Black Sunflower installer, service agency or your dealer. Seeds Shipping Weight: 429 lbs NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their *BTU will vary, depending on the type of fuel you use in your specifications and/or price without notice. appliance. Consult your Quadra-Fire dealer for best results. Quadra-Fire is a registered trademark of Hearth & Home Technologies. C. Glass Specifications This stove is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. D. Electrical Rating 115 VAC, 60 Hz, Start 5 Amps, Run 1.25 Amps May 2, 2014 7034-277B...
  • Page 4: Getting Started

    MT. VERNON AE Install Guide Getting Started A. Design, Installation & Location Considerations Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: 1. Appliance Location • Windows NOTICE: Check building codes prior to installation. • Air Intakes • Installation MUST comply with local, regional, state and • Air Conditioner national codes and regulations.
  • Page 5: Thermostat Wall Control Location

    MT. VERNON AE ITEM PART NUMBER PART NAME B. Thermostat Wall Control Location D. Inspect Appliance and Components The thermostat wall control’s location will have some affect • Open the appliance and remove all the parts and articles on the appliance’s operation. packed inside the Component Pack. Inspect all the parts and glass for shipping damage. • Maximum wire length from appliance is 100 feet (30.48m) continuous unspliced wire. Recommended 20 gauge wire, • Report to your dealer any parts damaged in shipment.
  • Page 6: Install Checklist

    This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. Customer: Date Installed: Lot/Address: Location of Fireplace: Installer: Dealer/ Distributor Phone #: Serial #: Model (circle one): MTVERNON-AE-CSB MTVERNON-AE-MBK MTVERNON-AE-PBK MTVERNON-AE-PDB MTVERNON-AE-PFT MTVERNON-AE-PMH WARNING! Risk of Fire or Explosion! Failure to install fireplace according to these instructions can lead to a fire or explosion. Appliance Install IF NO, WHY? Verified clearances to combustibles. (Pg. 8) Fireplace is leveled and liner is secured to appliance. (Pg. 18) Hearth extension size/height decided. (Pg. 22) Outside air kit installed. (Pg. 15) Floor protection requirements have been met.
  • Page 7: Dimensions And Clearances

    MT. VERNON AE Dimensions and Clearances A. Appliance Dimensions 14-1/16 in. 5-13/16 in. (147mm) (357mm) 3-13/16 in. (97mm) 2-9/16 in. 31-1/6 in. (65mm) (788mm) 29-3/6 in. (741mm) Figure 7.1 - Top View with Top Vent Adapter Figure 7.2 - Side View with Top Vent and 3 to 6 in (76-152mm) Adapter Adapter and 3 to 6 in (76-152mm) 10-3/8 in.
  • Page 8: Clearances To Combustibles (Ul And Ulc)

    MT. VERNON AE C. Hearth Pad Requirements (UL and ULC) B. Clearances to Combustibles (UL and ULC) Use a non-combustible floor protector, extending beneath appliance and to the front, sides and rear as indicated. Mea- sure front distance “M” from the surface of the glass door. Straight Back Against Wall Inches Millimeters...
  • Page 9: Vent Information

    MT. VERNON AE Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Figure 9.1 Termination Cap Restricted Area Air Supply Inlet Gas Meter All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 10: Avoiding Smoke And Odors

    MT. VERNON AE B. Avoiding Smoke and Odors Vent Configurations To reduce probability of reverse drafting during shut-down Negative Pressure, Shut-Down and Electrical Power conditions Hearth & Home Technologies strongly recom- Failure mends: To reduce the probability of back-drafting or burn-back in • I nstalling the pellet vent with a minimum vertical run of the pellet appliance during power failure or shut down con- 5 feet (1.52m). Preferably terminating above the roof...
  • Page 11: Negative Pressure

    • Ensure furnace and air conditioning return vents are not 2. Mobile Home: Approved for all Listed pellet vent. If using located in the immediate vicinity of the appliance the 3 inch (76mm) vertical Top Vent Adapter Kit or the 3 • Avoid installing the appliance near doors, walkways or to 6 inch (76-152mm) Top Vent Offset Adapter, use Listed small isolated spaces double wall flue connector. A Quadra-Fire Outside Air Kit • Recessed lighting should be a “sealed can” design must be used with manufactured home installations. • Attic hatches weather stripped or sealed 3. Residential: The 3 inch (76mm) vertical Top Vent Adapter Kit and the 3 to 6 inch (76-152mm) Top Vent Offset Adapter • Attic mounted duct work and air handler joints and seams are tested to use 24 gauge single wall flue connector or taped or sealed Listed double wall flue connector to Class A Listed metal chimneys, or masonry chimneys meeting International Residential Code standards for solid fuel appliances.
  • Page 12: Equivalent Feet Of Pipe

    MT. VERNON AE F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet Vent surfaces get HOT, can cause burns if of pipe which is a method used to determine pellet vent size. touched. Non-combustible shielding or guards Figure 12.1 may be required. Example of 3 Elbow-Rear Vent Termination Calculation Pellet Venting # of Feet of Multiplied Equivalent Components Component Elbows Pipe Feet Equivalent Feet 2 ft. Elbow or Tee Elbow Horizontal Pipe...
  • Page 13: Venting Systems

    MT. VERNON AE Venting Systems A. Alcove Figure 13.1 Minimum* Maximum Inches Millimeters Inches Millimeters Height 1092 Width 1016 Depth To Side Wall *All minimums listed are to a combustible surface. NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. • Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference. May 2, 2014 7034-277B...
  • Page 14: Through The Wall

    MT. VERNON AE B. Through The Wall Horizontal termination cap must be a minimum of 6 inches. NOTE: (152mm) from the wall. Approved for mobile home installa- In Canada, where passage through a wall or partition of tions. Must use 3 or 4 inch (76-102mm) “L” or “PL” Listed combustible construction is desired, the installation shall conform to CAN/CSA-B365 pellet venting or Listed double wall pipe and a Quadra-Fire Outside Air Kit in mobile homes. 2 in. Straight Out (51mm) Horizontal Minimum W all T ermination Thimble 6 in.
  • Page 15: Vertical Into Existing Class A Chimney

    We recommend a minimum of 60 inches (1524mm) vertical, however above the eave is preferred. Rain Cap All three installations are approved for mobile home installations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and Quadra-Fire Outside Flashing Air Kit in mobile homes. Single wall pipe is 12 in. (305mm) Minimum approved for residential installations only. Firestop *NOTE: Clearance to combustibles are for standard pellet pipe.
  • Page 16: Masonry

    MT. VERNON AE WARNING Fire Risk. Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211 • Factory-built chimney must be a minimum 6 inch (152mm) UL103 HT. F. Masonry Fireclay flue Concrete Cap liner with airspace Flashing 1 in. (25mm) clearance with firestop 1 in. (25mm) clearance 3 in. (76mm) minimum to 6 in. (152mm) combustible material minimum Sheathing...
  • Page 17: Appliance Set-Up

    MT. VERNON AE Appliance Set-Up A. Leg Leveling System B. Outside Air Kit Instructions 1. Thread Allen bolts through nuts until flush. Figure 17.1. The Allen bolts and nuts are included in the component pack inside the appliance firebox. CAUTION 2. Slide assembled nuts and bolts into slots on legs with the Never draw outside combustion air from: nuts on the bottom. Figure 17.2. Use a 5/32 in. (3.96mm) • Wall, floor or ceiling cavity Allen wrench to adjust legs up and down to desired level. • Enclosed space such as an attic or garage Figure 17.3 Included in Kit: 2 wire ties, 1 collar assembly, 1 termination cap assembly, 1 trim ring, fasteners. NOTE: 3 INCH ALUMINUM FLEX PIPE NOT INCLUDED. Tools Needed: Phillips head screw driver; wire cutters hole saw or jig saw.
  • Page 18: Top Vent Adapter Installation

    MT. VERNON AE C. Top Vent Adapter Installation 3 to 3 inch (76-76mm) Top Vent Adapter 3 to 6 inch (76-152mm) Top Vent Offset Adapter Installing the Top Vent Adapter Put a layer of high temperature silicone on the 3 inch (76mm) exhaust outlet.
  • Page 19: Optional Log Set Placement Instructions

    MT. VERNON AE E. Optional Log Set Placement Instructions 2 PIECE LOG SET INSTALLATION 1. Place the left log as shown. There are 2 indentations in the bottom of the log to fit over the screw heads in the firebox. Figures 19.1 and 19.2 2.
  • Page 20: Wall Control Thermostat Installation

    MT. VERNON AE F. Wall Control Thermostat Installation When mounting the wall control thermostat on the wall, be sure to follow your thermostat wall control’s installation instructions carefully. Wall Control Thermostat Wires Attach to Center 3 Screws NOTE: The wall control thermostat should be mount- ed on an inside wall and not in direct line with the Green White appliance convection air.
  • Page 21: Mobile Home Installation

    MT. VERNON AE Mobile Home Installation CAUTION You must use a Quadra-Fire Outside Air Kit for installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE An outside air inlet must be provided for the combustion MAINTAINED air and must remain clear of leaves, debris, ice and/or Do NOT cut through: snow. It must be unrestricted while the appliance is in • Floor joist, wall, studs or ceiling trusses. use to prevent room air starvation which causes smoke • Any supporting material that would affect the structural spillage. Smoke spillage can also set off smoke alarms. integrity. 2. The combustion air duct system must be made of metal. This unit is to be connected to a factory-built chimney It must permit zero clearance to combustible construc- conforming to CAN/ULC-S629, Standard for 650°C Facto- tion and prevent material from dropping into the inlet or ry-Built Chimneys.
  • Page 22: Accessory List

    Wire Harness Ignitor SRV7034-273 Wire Harness Power Out Ac AC Current 7034-220 MT. VERNON AE Wire Harness Power Out Dc DC Current 7034-221 Wire Harness Power Supply Receptacle SRV7034-233 Accessory List Wire Harness Snap Disc 7034-193 Wire Harness Thermostat SRV7034-200 ACCESSORIES 12 Volt Power Cord 12VCORD-AE Collar, Offset, Top Vent 812-3570 Damper, 3 Inch - Tall Vertical Installs Only PEL-DAMP3 Damper, 4 Inch - Tall Vertical Installs Only PEL-DAMP4 Firescreen SCR-7005 Log Set, (Sold as Set only) 2 Pc LOGS-60-AE-B Outside Air Kit OAK-3 Top Vent Adapter TPVNT-3 Vent Adapter, 3-4” 811-0720 Vent Adapter, 90, Cleanout 811-0610...
  • Page 23 MT. VERNON AE May 2, 2014 7034-277B...
  • Page 24 CONTACT INFORMATION Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL Read, understand and Leave this manual with • •...

Table of Contents