Page 6
GEM-RP2ASe2/GEM-K2AS Keypad Easy Program Menu
Enter the Dealer Security Code (default = 456789) for a new panel or enter your custom Dealer Program Code if
GEMINI
SYSTEM ARMED
programmed. Press the PRIOR/NO button repeatedly until "TURNON/PROG" is displayed. NOTE: If you pass
ENT A1
ENT A1
01/01/97 12:00AM
"TURNON/PROG", you can scroll back by pressing
NEXT/YES
A
1 2
3
E
D
PRIOR/NO
B
4
5 6
F
Mode. In each of the following steps, press
AREA
C
7 8 9 0
G
COMPUTERIZED SECURITY SYSTEM
R
forwards, the PRIOR/NO button to go backwards,
Ent A 1
#ZnXX
(Direct Entry)
Ent A 2
#ZnXX
(Direct Entry)
Ent F r
Zn#XX
(Direct Entry)
Ent2W F
Zn#XX
(Direct Entry)
Repor t
all Z n
Y/N
(Press YES or NO)
EntEE 1
Zn#XX
(Direct Entry)
EntFo l
Zn#XX
(Direct Entry)
X
GEM-P3200 Programming Instructions
Total Number of Zones in Area 1 (New Program Only)
•
Enter the total number of zones to be programmed for Area 1.
•
Valid entries are from 08 to 48. Directly enter the total number of zones, including leading zeros.
•
The system is based on groups of 4 zones each (after the first 8 zones), and will automatically round up to the
next group of 4. For example, if you enter 18, it will automatically convert this to 20 zones. Press
Press the NEXT/YES button to proceed.
Total Number of Zones in Area 2 (New Program Only)
•
Enter the total number of zones to be programmed for Area 2.
•
Valid entries are from 00 to 48. Directly enter the total number of zones, including leading zeros.
•
The system is based on groups of 4 zones each (after the first 8 zones), and will automatically round up to the
next group of 4. For example, if you enter 18, it will automatically convert this to 20 zones. Press
Press the NEXT/YES button to proceed.
Fire Zones in Area 1 (New Program Only)
•
Enter the zone number of any Fire Zones (including 2-wire, 4-wire or wireless).
•
Valid entries are from 01 to 48.
•
Directly enter each zone number, including leading zeros, and press
tional zone(s). Press the NEXT/YES button to proceed.
2-Wire Fire Zones in Area 1 (New Program Only)
•
Enter the zone number of any Fire Zone (from previous question) to be used with 2-wire smoke detectors.
•
Valid entries are 07 and 08. Directly enter each zone number, including leading zeros.
•
U
Press
to save, and repeat for any additional zone(s); press NEXT to proceed.
NOTE: Only zones which have been designated as Fire Zones can be programmed as 2 Wire Fire zones. JP3
must be set to "2-WF" position for 2-wire fire for Zones 7-8 (refer to Installation Instructions).
Local or Central Station Reporting System (New Program Only)
Press the NEXT/YES button for all zones to report; press the PRIOR/NO button for local system.
Exit/Entry Zones in Area 1 (New Program Only)
•
Enter the zone numbers of zones to be used as Exit/Entry zones.
•
Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
•
U
Press
to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
NOTE: Entry Delay time of 30 seconds and Exit Delay Time of 60 seconds will automatically be programmed.
Interior Zones in Area 1 (New Program Only)
•
Enter the zone numbers to be used as Interior Zones.
•
Valid entries are from 01 to 48. Directly enter each zone number, including leading zeros.
•
U
Press
to save and then repeat for any additional zone(s).
•
Press the NEXT/YES button to proceed.
•
All Interior zones will also be automatically programmed as "Exit/Entry Follower" and as "Power Up Delay" zones.
. Press the NEXT/YES button to enter the Dealer Program
B
to jump to the next screen, the NEXT/YES button to go
R
U
to save and
twice to exit at any time.
C
U
L
WI1184B 2/06
U
to save.
U
to save.
to save, and then repeat for any addi-
NAPCO Security Systems