RF RECEIVER S & SUPERVIS OR Y TIMER OP TI ONS
ADDRESS 3776
Number of RF
LEFT
RIGHT
Receivers
blank (•)
Default Number of Receivers = 0
RF SUPERVISORY
RF TRANSMITTER
TIMER
Type 0
Window/Door, 2 Pt.
Type 1
Window/Door, 2 Pt.
Type 2
Window/Door, 2 Pt.
Type 3
Window/Door, 2 Pt.
Type 4
Window/Door, 4 Pt.
Type 5
Type 6
Type 7
Smoke Detector
[Default = blank (•) 8 from address 3760-3767 (80 minutes)]
RF SUPERVISORY TIMERS
DATA ENTRIES
DELAY
LEFT
RIGHT
0 min.
blank (•) blank (•)
blank (•)
1
10 min.
blank (•)
2
20 min.
blank (•)
3
30 min.
blank (•)
4
40 min.
blank (•)
5
50 min.
blank (•)
6
60 min.
blank (•)
7
70 min.
blank (•)
8
80 min.
blank (•)
9
90 min.
blank (•)
0
100 min.
blank (•)
B
110 min.
blank (•)
C
120 min.
blank (•)
D
130 min.
blank (•)
E
140 min.
blank (•)
F
150 min.
1
blank (•)
160 min.
1
1
170 min.
1
2
180 min.
1
3
190 min.
1
4
200 min.
1
5
210 min.
1
6
220 min.
1
7
230 min.
1
8
240 min.
1
9
250 min.
1
0
260 min.
1
B
270 min.
1
C
280 min.
1
D
290 min.
1
E
300 min.
1
F
310 min.
2
blank (•)
320 min.
2
1
330 min.
2
2
340 min.
2
3
350 min.
2
4
360 min.
2
5
370 min.
X
GEM-P3200 Programming Instructions
DATA ENTRIES
RIGHT
RF Receiver(s)
blank (•)
None
1
1
2
2
3
3
4
4
ADDRESS
3760-3767
LEFT
ADDR
RIGHT
3760
3761
3762
3763
3764
PIR
3765
PIR
3766
3767
RF SUPERVISORY TIMERS
DATA ENTRIES
DELAY
LEFT
RIGHT
380min.
2
6
2
7
390 min.
2
8
400 min.
2
9
410 min.
2
0
420 min.
2
B
430 min.
2
C
440 min.
2
D
450 min.
2
E
460 min.
2
F
470 min.
3
blank (•)
480 min.
3
1
490 min.
3
2
500 min.
3
3
510 min.
3
4
520 min.
3
5
530 min.
3
6
540 min.
3
7
550 min.
3
8
560 min.
3
9
570 min.
3
0
580 min.
3
B
590 min.
3
C
600 min.
3
D
610 min.
3
E
620 min.
3
F
630 min.
4
blank (•)
640 min.
4
1
650 min.
4
2
660 min.
4
3
670 min.
4
4
680 min.
4
5
690 min.
4
6
700 min.
2550 min. = 42
F
F
Hr., 30 min.
( A D DR ES S 3 7 7 6 & 3 7 6 0 - 3 7 7 5 )
RF RECEIVERS: Up to 4 RF Receivers may be programmed.
NOTE: This allows wireless capability to the system, of up to 96
zones.
1. Select the number of receivers from the table shown.
2. Enter in corresponding right digit address location shown
(left digit is not used).
RF SUPERVISORY
RF TRANSMITTER
TIMER
Type 8
Smoke Detector
Type 9
Keyfob
Type A
Dual Tech.
Type B
Keyfob
Type C
Window/Door, 4 Pt.
Type D
PIR
Type E
Smoke Detector
Type F
Napco Glass Break
[Default = blank (•) 8 from address 3768-3775 (80 minutes)]
RF SUPERVISORY TIMERS: RF Supervisory Timers may be
programmed for each type of transmitter used. A transmitter will send
a transmission every time it is tripped, when there is NO activity, the
transmitter sends a status transmission about once an hour. If the
receiver does NOT receive ANY signal (a trip or a status) from a
transmitter in the time specified for transmitter type, a system trouble
"
E-04-NN
" will be displayed at the keypad.
1.
Select timer delay from the table shown.
programmed in increments of 10 minutes each. Valid entries
are (•)8-FF (80 minutes-2550 min) (2550 minutes = 42 hr,30
min).
WARNING: Timers have uncertainty of +/-30 minutes.
2.
Enter in corresponding address locations above (left and
right digits).
3.
For a desired timer not listed do the following:
6 Quotient
16 100
96
4 Remainder
A. Choose a desired timer (intervals of 10),
ex: 1440 min. (24 Hours)
B. Divide it by 10, ex: 1440/10 = 144
C. Divide it by 16
NOTE: These timers apply only to Supervised RF Transmitters (see
RF Transmitters in Easy Menu Driven Mode Programming).
L
WI1184B 2/06
ADDRESS
3768-3775
LEFT
ADDR
RIGHT
3768
3769
3770
3771
3772
3773
3774
3775
Timers are
Left Digit
Right Digit
NAPCO Security Systems