WI1184B 2/06
USER AUTHORITY LEVEL
KEYPAD DISPLAY FUNCTION MENU
FUNCTION
LEVEL*
DISPLAY ZN FAULTS
DISPLAY ZN BYPASSED
DISPLAY ZN DIRECTORY
ACTIVATE BELL TEST
DISPLAY PHONE #'S
DISPLAY SYS TRBL
DISPLAY FIRE ALARM
DISPLAY FIRE TRBL
DISPLAY OP/CL
ACTIVATE OVERVIEW
ACTIVATE CHIME
ACTIVATE WATCH
RESET SYSTEM TRBL
RESET SENSOR MSG
START EXIT TIME
FAULT FIND
ACTIVATE LOCATE
EZM ZONE FIND
ACTIVATE DIALER TEST
DISPLAY ALARM LOG
DISPLAY TOTAL LOG
DISPLAY FIRE LOG
DISPLAY OP/CL LOG
DISPLAY SYSTEM LOG
AUTOARM IN 1-4HRS
DISPLAY AUTOARM SCHD
ACTIVATE PROGRAM
ACTIVATE DOWNLOAD
DISPLY RF XMITTER STAT
RELAY CONTROL
Example: Program a code of "2222" for user 02, with User Option of "User Program", User "Level 3" and Access Control Option
"Keypad No. 1". Enter "2222" for a user code, "2 3" for user option and "blank(•) 1" for access control option.
CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described
U
above and press
to save. Similarly, to cancel a code, blank out each number of the code and press
save.
L
NAPCO Security Systems
NOTES:
*
Minimum Level required to access function
** Level-3 Code with appropriate user option
1
*** Requires Dealer Code
1
1
1
1
1
1
OPTIONS
1
Disabled
User Code not active in this area.
3
3**
Blocked View
Allows User Code to block another code from being viewed by another user.
1
An unblocked code cannot view a blocked code, but a blocked code can
view all codes. The master user code and the dealer program code can view
2
all codes.
3
User Program
User Program Option is enabled for Keypad 1 only, wherever it is connected
3
(any area). If enabled, Level 3 must also be enabled.
Bypass
Allows User Code to bypass zones.
1
***
Overview
This option, along with Level 3 Authorization, enables selection of
***
OVERVIEW mode at a keypad. This Mode provides a system status display
of all areas at a glance.
***
Arm Only
Prevents User Code from disarming this area.
3
3
Service
A Service Code has restricted arm/disarm rights; if an area is armed with a
3
Service Code, a "
3
on the GEM-RP1CAe2 keypad) and the area can be disarmed with any valid
User Code, including a Service Code. If the area is armed with OTHER than
3
a Service Code, it CANNOT be disarmed with a Service Code. This is
3
typically used to allow tradesmen access to premises under control of the
owner.
2
There are two types of Ambush Codes: (1) A 2-digit code (prefix) that is entered
Ambush
3
immediately prior to (and as part of) the regular User Code and (2) A separate
3**
and unique User Code. Disarming with an Ambush Code will cause a silent
report to be sent to a central station. Thus, should a user be forced to disarm, he
3
can silently signal an emergency while appearing to be merely disarming the
1
system.
1
Access
This is normally used to activate a door striker while an area is disarmed. A
code with the access option will not function as an arm/disarm code. When
the code is entered, the keypad will display "
Wire on the keypad will become Active Low (Ground Potential) for 7
seconds.
Related User Options: "Ambush
Code" (Address 0490), "Dealer Security Code" (Address 0500) & "Enable User Code by
Area" (Address 2500-2595).
USER OPTIONS
EXPLANATION
SERVICE ON
" appears on the GEM-RP2ASe2 keypad (a "
ENTER NOW
Code"
(Address
0495),
X
GEM-P3200 Programming Instructions
Page 11
S
"
" and the Brown
"Panel
Access
U
to save to

Hide quick links: