FUNCTION
CODE
OUTLINE
FUNCTION
CODE
OUTLINE
FUNCTION
CODE
OUTLINE
Carriage return
<CR>
(0D)H
The <CR> code is valid when the memory switch 3-1 = 1 (set to 0
at exfactory). When the <CR> code is valid, setting the memory
switch 3-0 will cause the <CR> to function as shown in the table
below.
Memory Switch Setting
MSW 3-1 = 0
MSW 3-0 = 0
MSW 3-1 = 1
MSW 3-0 = 1
Feed paper n lines
<ESC> "a" n
(1B)H (61)H n
< =
< =
1
n
127
After data in the line buffer is printed out, feeds the paper n lines.
Horizontal tab
<HT>
(09)H
The print position skips to the next horizontal tab position in line.
If the current position is after the final horizontal tab position that
can be executed, this code is ignored. (Underlining and overlining
do not take place in the spaces between characters set with the
horizontal tab function.)
18
<CR> Code Function
Ignored (at exfactory)
Same as <LF>
Prints only. No paper feed