FUNCTION
CODE
OUTLINE
n2
Treatment of missing data during reverse mode
"0" to "7"
Store
"8" to "F"
Delete
*1:
Valid only when using a parallel interface.
Set DIP SW 1-2 if you are using a serial interface.
Also, the conditions for BUSY and the automatic status are
disregarded.
*2:
Valid only when using a parallel interface.
For example, if you exit the reverse mode without the host
receiving the trailing data of the automatice status the
remainder of the status data will be handled as described
below.
Store:
Stores the remaining data and transmits it at the
next time the reverse mode is entered. If the
automatic status occurs, the new status will be
transmitted after that remaining data.
Delete:
Deletes the remaining data. It does not transmit
that data the next time the reverse mode is
entered. The new status data is transmitted from
the header field.
Initialize printer
<ESC> "@"
(1B)H (40)H
Initializes all the commands already set. However the following
parameters are not initialized: online switch valid/invalid
selection. Also, the line and data buffers are not cleared. The
DIP switches and the memory switches are not read in again.
The select/deselect state for addressable mode and DC1/DC3
mode is not affected.
43