Intermec PENKEY 6100 Programmer's Reference Manual page 65

Hide thumbs Also See for PENKEY 6100:
Table of Contents

Advertisement

SECTION 2
54
BUFFER_GET_FAILURE
write failure –– could not get a transmit buffer to send the data to the printer.
55
BAD_CONNECTION_HANDLE
open, write, or close failure –– a defective connection handle was encountered during
the flushing of the driver's coalescence buffer.
56
UNKNOWN_TRANSMIT_FAILURE
open, write, or close failure –– the link access protocol failed for "unknown" reasons
during an attempt to flush the driver's coalescence buffer.
57
WRITE_WITH_PRINTER_NOT_READY
write failure –– a write was attempted to the driver while the driver is in an error
state.
58
I_QUEUE_FULL
open, write, or close failure –– the driver could not get a queue for the transmission
of an information frame.
59
CONNECT_FAILURE
open failure –– after a successful discover of an IrDA device, a connection could not
be established.
60
DRIVER_CLOSED
write, read, ioctl, close failure –– an attempt was made to access the driver while the
driver was in a closed state.
61
NO_RECURSION
write, read, ioctl, close failure.
er.
62
BAD_LINK_CONTROL_FRAME_SIZE
open failure, link management failure –– the system did not receive the correct frame
size for a connect confirmation by IrLMP after the IrLAP link session was established
with the remote device.
63
LINK_MANAGEMENT_CONTROL_FRAME_EXPECTED
open failure, link management failure –– the system did not receive an IrLMP control
frame from the remote device after the IrLAP link session was established.
64
NOT_LINK_MANAGEMENT_CONNECT_CONFIRM
open failure, link management failure –– the system did not receive an IrLMP connect
confirm frame from the remote device after the IrLAP link session was established.
65
RECEIVE_FRAME_FAILURE
open failure, link management failure –– the system did not receive the IrLMP connect
confirm frame from the remote device that had a successful IrLAP link established.
66
READ_FAILURE_PRINTER_NOT_READY
read failure –– an attempt was made to read from the character stream with the connec-
tion not in the ready state.
67
READ_FAILURE_PRINTER_IN_NDM
read failure –– an attempt was made to read from the character stream with the connec-
tion in the normal disconnect mode.
68
READ_FAILURE_BAD_CONNECTION_HANDLE
read failure –– an attempt was made to read from the core, and the connection handle
used is no longer valid.
69
READ_FAILURE_UNKNOWN_STATUS
read failure –– an attempt was made to read from the core that resulted in the core
posting an unknown error.
70
WRITE_REQUEST_EXCEEDS_COALESCING_BUFFER
write failure –– the user's write buffer is too large to fit in the local coalescing
buffer and is being rejected.
less than 128 bytes at this time.
An attempt was made to recursively access the driv-
Present the data to the driver with a buffer size of
R
PEN*KEY
6100 Computer Programmer's Reference Guide
Supporting DOS Applications
2-13

Advertisement

Table of Contents
loading

Table of Contents