5. Set the DE-DIAG ID switch located on the additional disk enclosure.
The DE-DIAG ID switches on both adapters of the additional disk enclosure are
factory-set to "0". Make sure that both DE-DIAG ID switches are set to "0". If not,
set DE-DIAG ID switches on both adapters to "0".
6. Check that the two power switches on the additional disk enclosure are set to OFF.
7. Insert the power cords provided with the additional disk enclosure into the plugs on
the power supply units, and secure them with the power cord stoppers.
Figure 3-14 Connecting the Power Cord to the Power Receptacle
8. Insert the plugs of the power cords provided with the additional disk enclosure into
properly grounded AC outlets.
9. Power on the additional disk enclosure by setting the power switches of the
enclosure to ON.
3-12 Upgrading the System
Figure 3-12 Setting the DE-DIAG ID Switch to "0"
ON
Figure 3-13 Turning the Power Supply Off
4 3 2 1 ON
When DE-DIAG ID = "0"