Path Fail-Over Feature; Expand Lun; Dynamic Capacity Expansion - NEC Storage S1300 User Manual

Disk array unit
Hide thumbs Also See for Storage S1300:
Table of Contents

Advertisement

Path Fail-Over Feature

The disk array unit is equipped with two controllers to enable dynamic cross call
control. The two controllers can access all logical disks. If either of the controllers is
defected, the disk array unit can continue operation by using the remaining controller.
In order to use this feature, separately sold software is required as well as specific OS.
Note:

Expand LUN

This feature increases the number of logical disks available from the host.
On Windows NT/Windows 2000 and Solaris, the expand LUN feature is disabled
(factory-set). The setting can be changed with NEC Storage Manager (management
software).
Note:
processing unit (host) that does not support the expand LUN feature,
and this feature is turned on, the host might not recognize this disk
array unit. If such an event occurs, the default setting cannot be
restored with NEC Storage Manager (management software)
depending on the system configuration, resulting in system fault.

Dynamic Capacity Expansion

The addition of a single disk drive to the rank configured with RAID 5 allows the rank
logical disk capacity to be expanded. Configurations that can be expanded range from
2+P to 13+P.
Physical hard disk drives should be added one by one. An expansion can be started only
after the previous expansion is completed. The expansion operation can be started by
the management software (NEC Storage Manager).
When using this feature on a host system running with Solaris, label
replacement job is required after the capacity is logically expanded. If
the data before capacity expansion is saved, it can be restored even
if the label is placed on another partition. Otherwise, the data will be
lost. You do not need to reboot the host to perform this operation.
Make sure to backup data before executing the Dynamic Capacity
Expansion feature.
1-24 System Overview
HP-UX contains this feature.
When the disk array unit is connected to a basic
!
CAUTION

Advertisement

Table of Contents
loading

Table of Contents