7. MAINTENANCE

Periodical inspection and maintenance are very important for keeping your generating set in good
working condition. Be sure to shut down the set before performing any maintenance and put the
generator on dry and level ground.
Service Period (1)
Item
Engine oil
Air cleaner
Fuel strainer
cup
Spark plug
Valves
Fuel tank
Fuel hoses
Note:
(
1)
Perform at every indicated month or operating hour interval whichever occurs first. Log hours of
operation.
(2) Shorten maintenance intervals if the generator is operated in high ambient temperatures or dusty
conditions.
(2)
The above-mentioned items must be performed with the assistance of a trained Kipor generator
technician.
■ Use genuine Kipor parts or the equivalent. The use of replacement parts which are not of equivalent
quality may damage the generator and void the warranty.
Part Description
Spark Plug
Air Filter Element
Fuel Strainer
Spark Arrestor
To locate a parts dealer in North America, visit the website www.kipornorthamerica.com.
Each
use
Check
Change
Check
Clean
Clean
Clean
Adjust
Adjust
clean
Check
Every 2 years (Replace if necessary) (3)
First
Every 3
month or
months or
20 Hrs.
50 Hrs.
○(2)
Coast Distribution Number
66162
66187
66540
66269
14
Every 6
Each year
months or
or 300
100 Hrs.
Hrs.
○(2)
○(3)
○(3)