Electrical connection
Check that the master switch is off (position "0").
Connect the power cable to a properly installed electrical socket with
earthing and a 30 mA FI fault current safety switch. The socket must have
neutral 16A fusing on the mains side.

Switching on the machine

- Switch off the ignition.
- Set the pressure control valve to maximum pressure and close the detergent valve
- Open the gun and switch the master switch on.
The high pressure pump now presses the air out of the lines, and after a short time
the high pressure spray forms and the operating pressure is reached.
The machine is fitted with a Total-Stop-System. If the gun is closed for
longer than approx 20 seconds, the machine switches off automatically.
The machine restarts automatically when the gun is re-opened, provided
that the master switch is on..

Usage as a cold water high pressure cleaner

- Leave the ignition "OFF"
- Start cleaning
Usage as a hot water high pressure cleaner
- Set the target temperature on the thermostat using the "+" and "-" buttons.
- Switch the ignition "ON"
The oil burner starts to work. The water is heated up and kept
at the temperature you have set. The current water temperature
is shown in the "ACTUAL" display field.
Usage with detergents
- Wait until the pump has pressed the air out of the lines
- Put the chemical filter into a container of detergent
- Open the detergent valve.
The pump now draws detergent in and mixes it with the high pressure spray.
- Set the desired concentration of detergent.