Toshiba e-Studio 162 Service Manual page 85

Hide thumbs Also See for e-Studio 162:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
41
06
OC cover float detection
level (OC FLOAT LEVEL)
(Disabled when set to OC)
(Executable only when the
ADF/RADF is installed.)
43
01
Fusing temperature setting
(Normal copy) (FU TEMP)
04
Fusing temperature setting
in multi coy (FU TEMP
MULTI)
[Function]
When this test command is executed, the current set value is displayed. When [OK (ENTER)/START]
key is pressed, the mirror base unit moves to the ADF scan position to acquire the OC cover float
detection level.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the detection level is not acquired, ERR display is made. (Default: 0)
Note that, this test command must be executed with the OC cover closed.
If the value is 0, float detection is not performed in normal jobs.
[Operation]
1) Initial display
41-06 OC FLOAT LEVEL
2) [OK (ENTER)/START]
41-06 OC FLOAT LEVEL
EXECUTING...
[Function]
When this test command is executed, the current set code number is displayed. Press [
key to change the setting and press [OK (ENTER)/START] key to save the setting into the EERPOM.
The machine goes into the sub code entry standby mode.
Code
Set temperature (°C)
0
1
2
3
4
5
6
7
8
[Operation]
The operation is similar to test command 21-01.
[Function]
For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the temper-
ature set with test command 43-1 to the temperature set with this test command.
When this test command is executed, the current set code number is displayed. Enter the code num-
ber and press [OK (ENTER)/START] key to change the setting.
Code
Set temperature (°C)
0
1
2
3
4
5
[Operation]
The operation is similar to test command 21-01.
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 16
Details of function/operation
<Canceling - when C/CA key is pressed->
After canceling, the machine goes into the sub code entry
standby mode.
0
THE JOB IS BEING
CANCELED.
3) When the level is acquired:
41-06 OC FLOAT LEVEL
3) When the level is not acquired:
41-06 OC FLOAT LEVEL
Remark
160
165
170
175
180
185
190
Default
195
200
Remark
155
160
165
170
Default
175
180
**** OK
**** ERR
/
/10KEY]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio 151dE-studio 162dE-studio 151

Table of Contents