[11] MAINTENANCE
1. Maintenance table
Section
Developing
Developer
DV blade
DV side seal (F/R)
Process peripheral
Drum
2. Maintenance display system
Toner
Life
Remaining quantity
LED
Machine
Developer
Life
LED
Machine
Maintenance
LED
Machine
: Check (Clean, adjust, or replace when required.)
Parts
25K
NEAR EMPTY
About 10%
ON
Operation allowed
ON at 25K of the developer count.
Selection is available between Not Stop and Stop by Service Simulation (SIM 26-37) Setup.
(If Stop is selected, the LED will flash and stop at 25K.)
∗
Default: Not Stop
∗
Clear: SIM 24-06
Selection is available among 25K, 13K, 9K, 6K, 3K, and free (no lighting) with SIM 21-1.
Default: 25K
∗
∗
Clear: SIM 20-1
Not stop.
e-STUDIO162/162D/151/151D MAINTENANCE 11 - 1
: Clean
50K
75K
100K
8K
EMPTY
Flash
Stop
25K
✩
: Replace
: Adjust
: Lubricate
125K
Remark