Toshiba e-Studio 162 Service Manual page 107

Hide thumbs Also See for e-Studio 162:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
66
38
Time setting/check
(Executable only when the
FAX is installed.)
41
CI signal check (Executable
only when the FAX is
installed.)
[Function]
Use to check the time setting.
[Operation]
1) Initial display
SELECT TO SET
1:DATE
2:TIME
[CLEAR] key: FAX control is terminated.
2) Select 1
xxxx.xx.xx(xxx)
CHANGE?
1:YES 2:NO
"xxxx.xx.xx(xxx)" is the current value. (No revi-
sion of display)
3) Select 1
INPUT YEAR
(4 DIGITS)____.__.__
Select 2: Returns to "1) Initial display".
4) Enter the year in 4 digits.
INPUT MONTH
(1-12)
1998.__.__
5) Enter the month in 2 digits.
INPUT DAY
(1-31)
1998.01.__
6) Enter the day in 2 digits.
xxxx.xx.xx(xxx)
STORED?
1:YES 2:NO
"xxxx.xx.xx(xxx) is the entered value.
Select 2: Returns to "1) Initial display".
7) Select 1
STORED
After 2sec, returns to "1) Initial display".
[Function]
Use to check the CI signal.
When CI signal is detected, OFF → ON.
[Operation]
1) Initial display
CHECKING
PRESS CLEAR TO STOP
[CLEAR] key: FAX control is terminated.
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 38
Details of function/operation
CI:OFF
2) Select 2
xx:xx
CHANGE?
1:YES 2:NO
"xx:xx" is the current value.
3) Select 1
INPUT HOUR
(0-24)
__:__
Select 2: Returns to "1) Initial display".
4) Enter o'clock in 2 digits.
INPUT MINUTE
(00-59)
01:__
5) Enter minute in 2 digits.
xx:xx
STORED?
1:YES 2:NO
"xx:xx" is the current value.
Select 2: Returns to "1) Initial display".
6) Select 1
STORED
After 2sec, returns to "1) Initial display".

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio 151dE-studio 162dE-studio 151

Table of Contents