Toshiba e-Studio 162 Service Manual page 104

Hide thumbs Also See for e-Studio 162:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
66
13
Dial test (Executable only
when the FAX is installed.)
17
DTMF signal send (Max.
value) (Executable only
when the FAX is installed.)
[Function]
Use to the dial test.
[Operation]
I Dial test (PULSE)
1) Initial display
SELECT SIGNAL
1:PULSE
2:DTMF
[CLEAR] key: FAX control is termi-
nated.
2) Select 1
INPUT MAKE TIME
(0-15)
3) Enter the make time in 2 digits.
INPUT DIAL #
XXXX
XXXX: Default
After deleting with [CLEAR] key,
input can be made.
4) [OK (ENTER)] key
SEND yyPPS xxms
1:YES 2:NO
"yy" is the selected pulse 10 or 20.
"xx" is the input value.
Select 2: Returns to "2)" display.
5) Select 1
Switched to 10/20PPS set with
pulse selection inside.
6) After setting
SENDING yyPPS xxms
7) After completion of sending
TERMINATE ?
1:YES 2:NO
Select 2: Returns to "4)" display.
8) Select 1
TERMINATED
After 2sec, returns to "1) Initial display".
[Function]
Use to set the DTMF signal send (Max. value).
[Operation]
1) Initial display
INPUT DIAL #
[CLEAR] key: FAX control is terminated.
2) [10KEY] input
The content selected with signal send level
selection is set inside.
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 35
Details of function/operation
I Dial test (DTMF)
1) Initial display
SELECT SIGNAL
1:PULSE
[CLEAR] key: FAX control is terminated.
2) Select 2
SELECT HIGH LEVEL
1:DEFAULT 2:SOFT SW.
__
3) Select 1
SELECT LOW LEVEL
1:DEFAULT 2:SOFT SW.
4) Select 1
INPUT DIAL #
XXXX
XXXX: Default
After deleting with [CLEAR] key, input can be made.
4) [OK (ENTER)] key
H:xx
1:YES 2:NO
"xx" indicates HI, and "yy" indicates Low Soft SW.
Select 2: Returns to "4)" display.
5) Select 1
HI/LO is selected with the signal level inside.
6) After setting the signal send level
SENDING DTMF
7) After completion of sending
TERMINATE ?
1:YES 2:NO
Select 2: Returns to "4)" display.
8) Select 1
TERMINATED
After 2sec, returns to "1) Initial display".
3) Communication is started after setting the
signal send level.
SENDING SIGNAL MAX
PRESS CLEAR TO STOP
[CLEAR] key: Returns to "1) Initial display".
2:DTMF
↓ Select 2
INPUT VALUE
(0-15)
__
↓ Select 2
INPUT VALUE
(0-15)
__
L:yy

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio 151dE-studio 162dE-studio 151