Toshiba e-Studio 162 Service Manual page 73

Hide thumbs Also See for e-Studio 162:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
2
02
ADF sensor status display
(ADF SENSOR) (Disabled
when set to OC) (Executable
only when the ADF is
installed.)
03
ADF motor operation check
(ADF MOTOR CHK)
(Disabled when set to OC)
(Executable only when the
ADF is installed.)
06
RADF resist clutch operation
check (RADF RES.CHK)
(Enabled only when RADF is
set.) (Executable only when
the RADF is installed.)
08
ADF paper feed solenoid
operation check (ADF SPUS
CHK) (Disabled when set to
OC) (Executable only when
the ADF is installed.)
09
RADF reverse solenoid
operation check (RADF
SPFS CHK) (Enabled only
when RADF is set.)
(Executable only when the
RADF is installed.)
10
RADF paper exit gate
solenoid operation check
(RADF SGS CHK) (Enabled
only when RADF is set.)
(Executable only when the
RADF is installed.)
3
03
Shifter operation check
(SHIFTER CHK)
[Function]
The ON/OFF status of the ADF sensors can be checked with the LCD.
When a sensor is ON, the sensor name is displayed on the LCD.
Sensor
Document set sensor
ADF document transport sensor
ADF paper feed cover open/close sensor
[Operation]
1) Initial display
02-02 ADF SENSOR
[Function]
When [OK (ENTER)/START] key is pressed, the motor rotates for 10sec at the speed corresponding
to the set magnification ratio.
[Operation]
The operation is similar to test command 1-01.
[Function]
When [OK (ENTER)/START] key is pressed, the RADF resist clutch (SRRC) repeats ON for 500ms
and OFF for 500ms 20 times.
[Operation]
1) Initial display
02-06 RADF RES.CHK
EXECUTING...
[Function]
The ADF paper feed solenoid (SPUS) repeats ON for 500ms and OFF for 500ms 20 times by the use
of the solenoid drive control Bios.
[Operation]
1) Initial display
02-08 ADF SPUS CHK
EXECUTING...
[Function]
The ADF reverse solenoid (SPFS) repeats ON for 500ms and OFF for 500ms 20 times by the use of
the solenoid drive control Bios.
[Operation]
1) Initial display
02-09 RADF SPFS CHK
EXECUTING...
[Function]
The ADF paper exit gate solenoid (SGS) repeats ON for 500ms and OFF for 500ms 20 times by the
use of the solenoid drive control Bios.
[Operation]
1) Initial display
02-10 RADF SGS CHK
EXECUTING...
[Function]
The shifter is moved back and forth in four reciprocations.
[Operation]
1) Initial display
03-03 SHIFTER CHK
EXECUTING...
e-STUDIO162/162D/151/151D TEST COMMAND, TROUBLE CODES 10 - 4
Details of function/operation
Display item
SPID
SPPD
SDSW
2) When the sensor is ON:
02-02 ADF SENSOR
SPID SPPD SDSW

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio 151dE-studio 162dE-studio 151

Table of Contents