Overview; Features - Sony MSU-1000 Operation Manual

Master setup unit
Hide thumbs Also See for MSU-1000:
Table of Contents

Advertisement

Overview

Features

The MSU-1000 series and RCP-1000 series are remote
control panels for configuring and controlling Sony's studio
and broadcast cameras.
This section describes the features that are common between
the MSU-1000 series and RCP-1000 series.
Remote control panels
The RCP-1000 series of remote control panels is designed
mainly for operation. Use a remote control panel with a camera
on a one-to-one basis.
• The RCP-1000 is a compact control panel with specialized
basic operations. The iris and master black adjustment block
employs joystick type control. Up to six units can be
mounted in a 19-inch EIA rack.
• The RCP-1001 is a compact control panel with specialized
basic operations. The iris and master black adjustment block
employs dial (knob) type control. Up to six units can be
mounted in a 19-inch EIA rack.
• The RCP-1500 incorporates an LCD display with direct
operation switches and a touch panel, which makes it a
remote control panel that offers both ease of operation and
multifunctionality that compares favorably with the MSU.
The iris and master black adjustment block employs joystick
type control. Up to four units can be mounted in a 19-inch
EIA rack.
• The RCP-1501 incorporates an LCD display with direct
operation switches and a touch panel, which makes it a
remote control panel that offers both ease of operation and
multifunctionality that compares favorably with the MSU.
The iris and master black adjustment block employs dial
(knob) type control. Up to four units can be mounted in a 19-
inch EIA rack.
• The RCP-1530 incorporates an LCD display with a touch
panel, and a variety of settings are available to make this
remote control panel compare favorably with the MSU. It is
multifunctional while at the same time having a slim body
that is just 80 mm wide, which allows you to mount up to five
units in a 19-inch EIA rack. The iris and master black
adjustment block employs joystick type control.
Master setup units
The MSU-1000 series of master setup units are control panels
designed mainly for maintenance and configuration. These
control panels can centrally control multiple camera systems.
• The MSU-1000 is has a horizontally long shape and is
provided with various direct switches to make quick
configuration possible.
• The MSU-1500 has a compact vertically long shape and is
of the same height as the RCP-1500/1501/1530.
4
Overview
Operability suitable for basic camera
operations
This remote control panel is provided with the control functions
required to perform the basic operations of cameras to enable
the simple and accurate operation of various functions. The
operation buttons, adjustment knobs, and other controls are
arranged on the panel according to function and frequency of
use. Guard frames are provided around buttons that are vital
to the operation and setup of cameras to prevent the buttons
from being unintentionally operated.
Illuminated buttons with high visibility flash and light to notify
you of the operation status to enable operation even in dark
locations. Likewise, an illuminated panel surface is employed
to allow you to confirm function names even when the
surroundings are dark.
Building of a variety of control systems
With the exception of the RCP-1000/1001, it is possible to
connect by LAN cable in addition to connecting using CCA-5
cable. Therefore, when setting up a multi-camera control
system, not only can a system be built using the CNU-700 as
previously, but a system can also be built using a LAN. In a
system that uses CNU-700s, two camera command network
units (CNUs) can be used to control a camera system of up to
24 cameras. In a system that uses a LAN, a camera system of
up to 96 cameras can be controlled.
A LAN cable cannot be connected directly to the RCP-1000/
1001, but an equivalent network system can be built by
connecting to a LAN compatible camera control unit (CCU).
Support for operating multiple cameras
Various operations are made possible by using multiple
camera systems that support multiple cameras.
The following functions are provided to control the connected
cameras.
• Panel active function
This function always enables one control panel for one
camera to prevent unintentional operation. Even with a
control panel that does not have the panel active
permission, a camera can be operated using the parallel
function, with the exception of iris and master black
operations.
• ALL function
This function simultaneously turns on and off the functions
of all connected camera systems.
• RCP assignment function
This function changes the combination of an RCP and
2)
camera system.
• Master/subordinate function
This function makes changes in conjunction with the color
temperature of the specified camera system.
1)
2)
2) 3)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msu-1500

Table of Contents