Sony MSU-1000 Operation Manual page 14

Master setup unit
Hide thumbs Also See for MSU-1000:
Table of Contents

Advertisement

3 Shutter control block (MSU-1000 only)
DEG
ON
a DEG indicator
This indicator is lit when the shutter indication is an angle
value. Configure the setting with the switches in Shutter of the
Paint menu.
b SLS/SHUTTER/ECS indicators
The indicator corresponding to the selected function is lit.
Select a function in the menu.
SLS : Slow shutter mode
SHT : Shutter mode
ECS : ECS (Extended Clear Scan) mode
c ON button
This button is for turning ON/OFF the camera's SLS, shutter,
or ECS function. Pressing the button causes it to light and
turns ON the function, and pressing it again causes the button
to go out and turns OFF the function.
d Shutter speed display window
This window is for indicating the shutter speed that is currently
set.
e Shutter speed selection buttons
These buttons are for setting the shutter speed. Each press of
the v (up) button increases the shutter speed, and each press
of the V (down) button decreases it.
4 Monitor selection block (MSU-1000 only)
a PICTURE MONITOR buttons (MSU-1000 only)
These buttons switch the output signals from the PIX2
OUTPUT connector of the CCU. Press the button for the signal
you want to output. The signal corresponding to the lit button
is output.
R/G/B/ENC (encode): Select the signal to output.
Simultaneously pressing the R, G, and B buttons allows
you to superimpose the signals.
b WAVEFORM MONITOR button (MSU-1000 only)
These buttons switch the output signals from the WF2
OUTPUT connector of the CCU. Press the button for the signal
you want to output. The signal corresponding to the lit button
is output.
R/G/B/ENC (encode): Select the signal to output.
Simultaneously pressing the R, G, and B buttons allows
you to superimpose the signals.
SEQ (sequence): Changes the sequence mode. The CCU
and WF monitor need to be connected and configured.
14
Names and Functions of Parts
SLS
SHT
ECS
SHUTTER
5 GAMMA (gamma selection) buttons and display
window (MSU-1000 only)
a Gamma display window
This window is for displaying the setting value (decimal value)
of the step gamma.
b Standard value indicator
This indicator lights when the standard value is set in the
Standard Indication menu. It lights in green for a standard
state, and amber for a non-standard state.
c Step gamma selection buttons.
Selects the gamma in steps.
Each press of the v (up) button decreases the value, and each
press of the V (down) button increases it. Pressing and
holding one of the buttons changes the gamma value
continuously.
6 Filter control block
MSU-1000
ND
FILTER
CONTROL
CC
a FILTER CONTROL button
This button is lit when the MSU has the filter servo control
permission. Pressing the button when it is not lit switches the
control permission to the MSU.
b Standard value indicators
These indicators light when the standard value is set in the
Standard Indication menu. They light in green for a standard
state, and amber for a non-standard state.
c ND filter selection buttons
Selects or indicates the ND filter.
d CC (color temperature conversion) filter selection
buttons
Selects or indicates the CC filter.
1
2
3
4
5
A
B
C
D
E