Masport MONTEREI Installation Instructions Manual
Masport MONTEREI Installation Instructions Manual

Masport MONTEREI Installation Instructions Manual

Direct vent

Advertisement

Quick Links

DIRECT VENT GAS STOVE
INSTALLATION AND OPERATING INSTRUCTIONS
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT
FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS
* DO NOT TRY TO LIGHT ANY APPLIANCE.
* DO NOT TOUCH ANY ELECTRIC SWITCH;
• IMMEDIATELY CALL YOUR GAS SUPPLIER FROM YOUR
NEIGHBOURS PHONE. FOLLOW THE GAS SUPPLIERS
INSTRUCTIONS.
• IF YOU CAN NOT REACH YOUR GAS SUPPLIER, CALL THE FIRE
DEPARTMENT (911)
• OPEN WINDOW/EXTINGUISH ALL FLAMES.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
• INSTALLATIONS AND SERVICE MUST BE PERFORMED BY A
QUALIFIED INSTALLER, SERVICE AGENCY OR YOUR GAS
SUPPLIER.
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
MODEL: MONTEREI

Advertisement

Table of Contents
loading

Summary of Contents for Masport MONTEREI

  • Page 1: For Your Safety

    DIRECT VENT GAS STOVE INSTALLATION AND OPERATING INSTRUCTIONS MODEL: MONTEREI WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS * DO NOT TRY TO LIGHT ANY APPLIANCE.
  • Page 2 THIS MANUAL CONTAINS IMPORTANT USER INFORMATION. KEEP THIS MANUAL WITH THE FIREPLACE AFTER INSTALLAITON IS COMPLETE. ATTENTION THE MONTEREI STOVE IS SHIPPED FROM THE FACTORY AS A DIRECT VENT NATURAL GAS FREESTANDING ROOM HEATER. TO COMVERT TO PROPANE PLEASE FOLLOW THE DIRECTIONS IN THIS MANUAL. ALL...
  • Page 3: Table Of Contents

    11 nstalling the log set page 15 peration page 17 ighting and operating instructions page 18 emote control page 19 aintenance page 22 onterei components page 25 ntacting Metal Fab page 27 Masport Monterei Direct Vent Gas Fire...
  • Page 4: General Information

    Appliances For Use at High Altitudes. This gas appliance has been tested in accordance with NZS5262:2003 The installation of the Monterei Direct Vent Room Heater must conform with local codes, or in the absence of local codes, with NZS5261 and AG601 and these instructions. (EXCEPTION: Do not derate this appliance for altitude.
  • Page 5 Specifications MONTEREI DIRECT VENT GAS HEATER NATURAL GAS AND LIQUID PROPANE MONTEREI DIRECT VENT CERTIFIED TO:ANSI Z21.88b-2001 /CSA 2.33b-2001 VENTED GAS FIREPLACE HEATERS FUEL MANIFOLD PRESSURE – MIN/MAX 0.32/0.87 kPa 0.89/2.61 kPa MIN. INLET SUPPLY PRESSURE FOR ADJUSTMENT 1.37 kPa 2.74 kPa...
  • Page 6 MEASURE SIDE CLEARANCES AS SHOWN IN FIGURES 5 AND 6 FROM THE OUTER EDGE OF THE CAST IRON STOVE TOP. MEASURE THE REAR CLEARANCES FORM THE OUTERMOST SURFACE OF THE STEEL REAR SKIRT. THE MONTEREI IS APPROVED FOR ALCOVE INSTALLATION SEE FIG. 3. Masport Monterei Direct Vent Gas Fire...
  • Page 7 THE VENT SYSTEM REQUIREMENTS: NOTE: WE DO NOT RECOMMEND THE USE OF WALLPAPER NEXT TO THIS STOVE. OVER TIME, RADIANT HEAT MAY CAUSE THE WALLPAPER TO SHRINK, OR MAY ADVERSELY AFFECT THE BINDERS IN THE WALLPAPER ADHESIVE. Masport Monterei Direct Vent Gas Fire...
  • Page 8: Ent Termination Clearances

    • For installations using Simpson DuraVent pipe, parallel installations with minimum wall clearance have restricted access for connecting the Horizontal Vent Cap straps to the vent pipe. See the maker’s instructions for recommended installation procedures. Masport Monterei Direct Vent Gas Fire...
  • Page 9 Vertically below an openable window, door, or non-mechanical air inlet, or any other opening into a building, with the exception of sub- floor ventilation (see also Note (I)): see table on next page Masport Monterei Direct Vent Gas Fire...
  • Page 10 A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and free flow of air at the appliance is achieved. Fig 9. Vent termination clearances Masport Monterei Direct Vent Gas Fire...
  • Page 11 Masport Monterei Direct Vent Gas Fire...
  • Page 12 Porcelain enamelled surfaces are fragile. Handle porcelain enamelled castings with care. Before you begin assembly, read this section of the manual to familiarize yourself with the procedures. The installation will be easiest if you follow the steps in the order presented. Masport Monterei Direct Vent Gas Fire...
  • Page 13: Ssembly Procedures

    ASSEMBLY PROCEDURES Venting System Assembly - Direct Vent The Monterei is approved for installation only with Masport direct flue heater systems. Install Restrictor Plate 1. Install the Restrictor Plate. Consult the ‘Vent Run Specifications’ to determine whether the restrictor plate is needed. If so, put the restrictor plate in place within the inner flue collar as shown in Figure 22.
  • Page 14 (not supplied) to fasten the lower portion of the snorkel. Fasten the brackets to the wall first, and then fasten to the snorkel with self-tapping #8 x 1/2” sheet metal screws. Extend the vent pipes out as far as the protruding wall face. Masport Monterei Direct Vent Gas Fire...
  • Page 15 9. Install the storm collar and seal around the joints. (Fig. 37) 10. Add additional vent lengths to achieve the proper overall height. 11. Apply cement to the inner and outer termination collars and install the terminal cap. Masport Monterei Direct Vent Gas Fire...
  • Page 16: Nstalling The Log Set

    Installing the Log Set Remove the logs from their packaging and inspect each piece for damage. DO NOT INSTALL DAMAGED LOGS. Masport Monterei Direct Vent Gas Fire...
  • Page 17 Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Monterei may be converted from one gas to another using the appropriate Fuel Conversion Kit listed on page 19.
  • Page 18: Peration

    Flame Characteristics It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the figures below. If any of the flames appear abnormal, call a service person. Masport Monterei Direct Vent Gas Fire...
  • Page 19: Lighting Procedure

    OFF position. The safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled down sufficiently (elapsed time will vary based on thermocouple type). • Switching off the remote is not necessary. Masport Monterei Direct Vent Gas Fire...
  • Page 20: Emote Control

    You may press AUTO to verify the set-temperature and then press TIMER to return to timer mode. • You may press either the ( ) or ( ) button from any mode for manual override. Masport Monterei Direct Vent Gas Fire...
  • Page 21 (less than 1m/3ft as this could, in very rare cases, produce a electronic switching error. This error could block the motor when the knob reaches the end points of its turning radius. The knob must then be turned manually to free the blockage. Masport Monterei Direct Vent Gas Fire...
  • Page 22 FUEL CONVERSION INSTRUCTIONS EXAMPLE OF CHART RECOMMENDATION 19,000 BTU/h = 20.04 MJ/h 20,000 BTU/h = 21.1 MJ/h 28,000 BTU/h = 29.54 MJ/h Masport Monterei Direct Vent Gas Fire...
  • Page 23: Aintenance

    MAINTENANCE Your Monterei Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly. Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician.
  • Page 24: Glass Replacement

    Refer to previous instructions for removal of the damaged glass frame. Gasket Replacement The Monterei Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer.
  • Page 25 Figure 70. The flames will be blue during the first 15-20 minutes of operation, and will gradually turn to yellow after that. Do not use your stove if the flame pattern differs from that shown here. Contact your Masport dealer or a qualified technician for help. Masport Monterei Direct Vent Gas Fire...
  • Page 26 EXPLODED VIEW – SERVICE PARTS Monterei MONTEREI Direct Vent Gas Heater LIST ALL PARTS OF STOVES (??). Masport Monterei Direct Vent Gas Fire...
  • Page 27 Metal Fab Ind (2004) LTD (hereinafter referred to collectively as the Company) warrants that your new Masport Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
  • Page 28 LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All MASPORT gas stoves. Masport Gasfires are distributed in New Zealand by GLEN DIMPLEX AUSTRALASIA, 38 HARRIS ROAD, EAST TAMAKI PO Box 58-473, Greenmount, Auckland, New Zealand For servicing heater call 0800 666 2824 New Zealand...

Table of Contents