Lighting Procedure - Masport MONTEREI Installation Instructions Manual

Direct vent
Table of Contents

Advertisement

Lighting Procedure

Turn knob A slightly left towards the ignition position until reaching stop, press down and
hold for five seconds (only pilot gas flows).
Continue pressing down knob A while turning further left to activate piezo, continue to
hold down for 10 seconds after pilot burner has been lit. If pilot does not light, steps 1 and
2 can be repeated immediately.
Upon lighting, release knob and turn further left to ON position. Pilot gas flows and main
gas flows in accordance to the temperature setting (knob B).
Adjusting Temperature
To turn the fire on and/or to increase the flame height, press the UP button of the remote
handset. Continue pressing until the desired flame height is obtained. Press and hold the DOWN
button to reverse the procedure. The receiver is equipped with a built-in delay, recognizable by
the flickering light, to facilitate fine adjustment of the flame. The motorized valve is equipped with
a slip clutch, allowing manual adjustment of main gas by turning knob B.
Shut-off Procedure
Turn knob A right until reaching stop. In this position only pilot gas flows.
To shut the valve off completely, press down slightly and continue turning right from
pilot position to the OFF position. The safety interlock prevents re-ignition of the pilot
flame until the thermocouple has cooled down sufficiently (elapsed time will vary
based on thermocouple type).
Switching off the remote is not necessary.