Emote Control - Masport MONTEREI Installation Instructions Manual

Direct vent
Table of Contents

Advertisement

REMOTE CONTROL
Set the display
After connecting the battery or by simultaneously pressing AUTO and TIMER, the display
flashes. You are in set mode.
From set mode, press AUTO to switch from ° F (and 12 hour clock) to ° C (and 24 hour
clock) or vice versa.
The display will automatically return to manual after some time, but you may immediately
return to manual by depressing the TIMER button.
Set the current time
After connecting the battery or by simultaneously pressing AUTO and TIMER, the display
flashes. You are in set mode.
From set mode, press ( ) to set the hour and ( ) to set the minute.
Wait or press TIMER to return to "manual" mode.
Programming the Desired Set Temperature
Press AUTO until the display flashes.
Press ( ) or ( ) to set the desired temperature.
Wait or press AUTO to switch to automatic mode.
A sensor in the transmitter measures the room temperature. The controller compares the
room temperature with the set temperature and sends a signal to the receiver to turn the
gas valve motor, which adjusts the flame height accordingly.
Programming the Timer
Press TIMER until P1* flashes (period 1, heating cycle on).
Set the time for the beginning of the first heating period by pressing ( ) for hour and
( ) for minute.
Press TIMER again; P1w appears.
Set the time for end of the first heating period.
Press TIMER again to set the second heating period P2w (heat off).
Store both heating periods by pressing TIMER again.
If only one heating period is desired, program the same time for P2* and P2w.
Manual Mode (MAN in display) for Manual Flame Height Adjustment
Press ( ) to turn on the fire (main burner) or to increase flame height.
Press ( ) to decrease flame or to turn down to pilot.
To incrementally increase or decrease the flame height lightly tap either the ( ) or ( )
button.
The "send" symbol appears in the upper left corner of the display when either button is
deprmasportd.
The LED of the receiver flashes when know B of the valve reaches the end stops.
Automatic Mode (AUTO in display) for Temperature Control
Briefly press AUTO. The set temperature will appear briefly before the display reverts to
the room temperature.
Timer Mode (TIMER in display)
During heating periods P1* and P2*, the temperature is controlled in the same manner
as in automatic mode.
When the timer program turns to w (heating cycle off), the motor will turn the valve to
pilot and there is no temperature control. This minimises battery consumption.
You may press AUTO to verify the set-temperature and then press TIMER to return to
timer mode.
You may press either the ( ) or ( ) button from any mode for manual override.
Masport Monterei Direct Vent Gas Fire
19