Masport Mackenzie R10000 Installation Specification Sheet
Masport Mackenzie R10000 Installation Specification Sheet

Masport Mackenzie R10000 Installation Specification Sheet

(dry & wet)
Hide thumbs Also See for Mackenzie R10000:

Advertisement

Quick Links

INSTALLATION SPECIFICATION SHEET
These instructions must be used in conjunction with the 'General Installation Instructions' for Masport
wood fires.
Important Note: Masport Mackenzie R10000 model needs to be installed with specific flue shield, flue divertor
plate and 500x500mm ceiling plate. The Glen Dimplex warranties will void unless fitted with these
components, which are supplied with the fire and Masport flue kit GDFLU013M.

CLEARANCE REQUIREMENTS

This fire has been tested and complies to the Australian/New Zealand Standard AS/NZS 2918:2001 and all
installations must be in accordance with the minimum clearances to combustibles indicated in these instructions.
The minimum clearances to combustables may be reduced if the combustable walls are shielded with an approved
non-combustable material. Details of suitable materials and appropriate clearance reduction factors are present in
Section 3 of AS/NZS 2918:2001.

POSITIONING YOUR FREE-STANDING WOODFIRE

NEW ZEALAND
MINIMUM DISTANCES TO HEAT SENSITIVE WALLS (mm)
MODEL
FLUE SYSTEM & FLUE SHIELD
MASPORT FLUE + MASPORT 900mm
Mackenzie R10000
DOUBLE SKIN SHIELD + TOP FLUE
(SW)(Dry & Wet)
DIVERTER PLATE + 500x500 Ceiling Plate
§ Valid only when the room walls are at 90° to each other.
‡ Note: Clearances are for fire hazard only. For durability of finishes or surfaces you should contact the relevant
manufacturer for their specification. Masport accepts no responsibility for the deterioration of surfaces or finishes.
MODEL
A
B
150
400
160
Page 1 of 5
Mackenzie R10000 (NZ)
(DRY & WET)
E
F
G
350
795
PRT. NO.
DATE:
H
550
778
583571
01.07.2014

Advertisement

loading

Summary of Contents for Masport Mackenzie R10000

  • Page 1: Clearance Requirements

    These instructions must be used in conjunction with the 'General Installation Instructions' for Masport wood fires. Important Note: Masport Mackenzie R10000 model needs to be installed with specific flue shield, flue divertor plate and 500x500mm ceiling plate. The Glen Dimplex warranties will void unless fitted with these components, which are supplied with the fire and Masport flue kit GDFLU013M.
  • Page 2 1070 Mackenzie R10000 (SW)(Dry & Wet) RDS = MASPORT DOUBLE SKIN SHIELD 900mm HIGH + TOP DIVERTER PLATE + 500x500 Ceiling Plate AFP = ASH FLOOR PROTECTOR Ø for minimum constructional requirements see general installation instructions. # Valid only when the fire is exactly at its minimum allowable wall clearance.
  • Page 3 Floor Protector Distance MODEL PROTECTOR Shield above Floor TYPE 1498 1294 Mackenzie R10000 (SW)(Dry & Wet) RDS = MASPORT DOUBLE SKIN SHIELD 900mm HIGH + TOP DIVERTER PLATE + 500x500 Ceiling Plate AFP = ASH FLOOR PROTECTOR Page 3 of 5...
  • Page 4 Seismic Restrain Holes location MODEL Mackenzie R10000 (SW)(Dry & Wet) Seismic Restrain - In New Zealand and some part of Australia, it is required that the wood fire and floor protector are secured to prevent shifting in the event of an earthquake. This is best done by fastening the wood fire right through the protector to the floor, using two screws not less than 12 guage or the equivalent size of coach bolts or toggle fasteners.
  • Page 5 THIS FLUE INSTALLATION DIAGRAM BELOW IS VALID FOR NZ INSTALLATIONS ONLY. FOR INSTALLATIONS IN AU PLEASE REFER TO SPECIFIC FLUE INSTALLATION SPECIFICATIONS SUPPLIED BY FLUE MANUFACTURER. Page 5 of 5...