INSTALLATION SPECIFICATION SHEET
These instructions must be used in conjunction with the 'General Installation Instructions' for Masport
wood fires.
Important Note: Masport Mackenzie R10000 model needs to be installed with specific flue shield, flue divertor
plate and 500x500mm ceiling plate. The Glen Dimplex warranties will void unless fitted with these
components, which are supplied with the fire and Masport flue kit GDFLU013M.
CLEARANCE REQUIREMENTS
This fire has been tested and complies to the Australian/New Zealand Standard AS/NZS 2918:2001 and all
installations must be in accordance with the minimum clearances to combustibles indicated in these instructions.
The minimum clearances to combustables may be reduced if the combustable walls are shielded with an approved
non-combustable material. Details of suitable materials and appropriate clearance reduction factors are present in
Section 3 of AS/NZS 2918:2001.
POSITIONING YOUR FREE-STANDING WOODFIRE
NEW ZEALAND
MINIMUM DISTANCES TO HEAT SENSITIVE WALLS (mm)
MODEL
FLUE SYSTEM & FLUE SHIELD
MASPORT FLUE + MASPORT 900mm
Mackenzie R10000
DOUBLE SKIN SHIELD + TOP FLUE
(SW)(Dry & Wet)
DIVERTER PLATE + 500x500 Ceiling Plate
§ Valid only when the room walls are at 90° to each other.
‡ Note: Clearances are for fire hazard only. For durability of finishes or surfaces you should contact the relevant
manufacturer for their specification. Masport accepts no responsibility for the deterioration of surfaces or finishes.
MODEL
A
B
150
400
160
Page 1 of 5
Mackenzie R10000 (NZ)
(DRY & WET)
E
F
G
350
795
PRT. NO.
DATE:
H
R§
550
778
583571
01.07.2014