Download Print this page

DKS 115 VAC 6004 Quick Start Manual

Advertisement

Quick Links

QUICKSTART "BASIC" GUIDELINES FOR MODEL 115 VAC 6004 - FOR GATES UP TO 8 FEET, 300LBS AND "OPENING TO THE INSIDE"
B
C
A
Gate Attachment Bracket
Opens to the
Inside
90°
Securely mount control box near the operator
with appropriate hardware (not supplied).
Top Limit
Ring
Coaxial
Cable
Control
Antenna
(Not
Box
Supplied)
Bottom
Limit Ring
Slow Down LED
D
J
Limit LED

Limit Switches

Circuit board power must be ON
when adjusting the limit rings, LEDs
will light while turning the limit rings.
Operator
Disassembly
Left-Side Position
D
O
O
R
K
I
N
G
C o
v e r
Remove cover and 2 thru-bolts to remove
and install the mounting bracket.
Left-Side Orientation
M o
u n
The mounting bracket and motor can be
t i n
B r a
g
c k e
flipped for right-side opening direction.
t
M o
t o r
U n
l o c
k
Arm Assembly
L o
c k
Manual Release
Arms MUST be
installed level!
Note: Lock and unlock directions will be reversed
when motor is in the right-side orientation.
Position of Operator and Arms
"A" inches
"B" inches
C max. inches
2.50 - 4.25
4.25 - 5.00
28.75
4.25 - 6.25
4.25 - 5.00
28.25
6.25 - 8.25
4.25 - 5.00
28.00
8.25 - 10.25
4.25 - 5.00
27.25
10.25 - 12.25
4.25 - 5.00
27.00
12.25 - 14.00
4.25 - 5.00
26.25
Note: Linking arm must be in the center hole of the gate
attachment bracket.
Operator Mounting
Options
Top
D O O R K I N G
Middle
Support Bar
D O O R K I N G
A support bar must be used if the
Operator
operator is mounted in the middle
Cable
of the gate and span the entire
length of the gate to support the
gate pickets. The pickets will bend
Bottom
if not supported.
D O O R K I N G
Right-Side Position
Right-Side Orientation
k
l o c
U n
c k
L o
Lockpin
Lockpin
Spacing
Install the gate attachment
Washers
bracket to the gate.
Retaining Ring
Model 115 VAC 6004 is intended for installation only on swing gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the
6004 Actuator Arm and Control Box Mounting manual and the 115 VAC Control Box Wiring/Owner's manual.
Installing Mounting Bracket and Gate Attachment Bracket
Brackets MUST be
installed level!
Left-Side
"Bottom"
Position
shown.
1 5/8"
Attach mounting bracket to pilaster or wall with four (4) #10
screws and suitable expansion hardware (Not supplied).
Single Channel Exit
Plug-In Loop Detector
1
2
G
3
4
5
6
7
D
H
1
2 3 4 5 6 7 8
Operator
Cable
G
SINGLE/PRIMARY
1. Brown
Coaxial Cable Antenna
2. Blue
Actuator Cable
3. Orange
(Not Supplied)
Circuit Board
4. Red
Connection
5. Yellow
6. Green
Copyright 2013 DoorKing, Inc. All rights reserved.
7. Green/Yellow
Brackets MUST be securely attached.
Extreme force will be exerted on
brackets during normal gate cycling.
Weld gate attachment bracket to gate or
use two (2) suitable screws (Not supplied).
H
KEY SWITCH BUTTON:
Cycles operator when pressed.
I
RESET BUTTON:
Resets circuit board.
Mounting Holes
C
C
9410
9409
Dual Channel
Reverse and Shadow
Plug-In Loop Detector
A
I
E
DO NOT connect the
Battery Plug
Primary operator to
this connection.
Connect Secondary
operator ONLY.
B
Relay must be set
to N.O. for shadow
loop.
J
AC Power Switch
4302
F
9 10 11 12 13 14 15 16 17 18 19 20
Mounting
Hole
Chassis
Alarm
Ground
Reset
Tip:
Never run low voltage
rated wire insulation in the
same conduit as high voltage
C
rated wire insulation. Keep
them in separate conduits.
Loop Wires
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Board Adjustments
Typical Settings for Single Operator with Plug-In Loops
See reverse side.
1. Direction
Primary
operator opens.
A
2. OFF
B
3. OFF
4.
ON
Auto-Close Timer
5. ON - Shadow Loop
6. OFF
1
23
7. OFF
Adjust 1 to 23 sec.
8. OFF
SW 1
1. ON - Relay for Dual Plug-In Shadow Loop
2. OFF - Relay for Dual Plug-In Shadow Loop
3. OFF
Note: Please refer to the
4. OFF
Wiring/Owner's manual for
SW 2
more information.

Loop Detectors

C
Not included - Refer to the Wiring/Owner's
manual and Loop Information Manual
(available free from www.dkaccess.com) for
more information.

Radio Receiver

D
Not included - Refer to a specific Radio
Receiver Manual (available from
www.dkaccess.com) for more information on
radio receivers and antenna installation. See
reverse side for wiring.
Battery Connection
CAUTION
E
Do not connect the battery plug to the
circuit board until power is needed to
test the operator.
115 VAC Connection
CONTROL BOX MUST BE
DANGER
PROPERLY GROUNDED!!
F
HIGH VOLTAGE!
Tip:
It is recommended
White - Neutral
that a surge suppressor
Black - 115 VAC Hot
be installed on the high
Green - Chassis Ground
voltage power lines.
Note: To turn-off ALL power to the operator, the AC
power switch must be turned off AND the battery
plug must be disconnected from the circuit board.
Wire Size
Distance
115 VAC Input
14 AWG
Up to 200 ft
Power Wire
12 AWG
Beyond 200 ft
6004-066-C-1-13

Advertisement

loading

Summary of Contents for DKS 115 VAC 6004

  • Page 1: Loop Detectors

    QUICKSTART “BASIC” GUIDELINES FOR MODEL 115 VAC 6004 - FOR GATES UP TO 8 FEET, 300LBS AND “OPENING TO THE INSIDE” Model 115 VAC 6004 is intended for installation only on swing gates used for vehicles. Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the Position of Operator and Arms 6004 Actuator Arm and Control Box Mounting manual and the 115 VAC Control Box Wiring/Owner’s manual.
  • Page 2 QUICKSTART “BASIC” GUIDELINES FOR MODEL 115 VAC 6004 - DIP-SWITCH AND WIRING REFERENCE Model 115 VAC 6004 is intended for installation only on swing gates used for vehicles. Main Terminal Pedestrians must be supplied with a separate access opening. For safety and installation instructions, please refer to the 6004 Actuator Arm and Control Box Mounting manual and the 115 VAC Control Box Wiring/Owner’s manual.