DKS 6050 Series Installation & Owner's Manual

DKS 6050 Series Installation & Owner's Manual

Vehicular swing gate operator
Hide thumbs Also See for 6050 Series:

Advertisement

Quick Links

Installation/Owner's Manual
Use this manual for circuit board 4502-010 Revision AA or higher.
For operators manufactured January 2016 and later.
P o
s t M
o u
n t
d M
P a
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
UL 325 Compliant
n t
o u
Copyright 2016 DoorKing, Inc. All rights reserved.
Series 6050 and 6100
Series 6050 and 6100
Vehicular Swing Gate Operator
EXTERNAL ENTRAPMENT PROTECTION MUST be
installed or the gate operator WILL NOT function.
Circuit Board
Serial Number
and Revision Letter:
Copyright 2009 DoorKing, Inc. All rights reserved.
6050-065-D-2-16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6050 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DKS 6050 Series

  • Page 1 Installation/Owner’s Manual Series 6050 and 6100 Series 6050 and 6100 Vehicular Swing Gate Operator Use this manual for circuit board 4502-010 Revision AA or higher. 6050-065-D-2-16 For operators manufactured January 2016 and later. EXTERNAL ENTRAPMENT PROTECTION MUST be installed or the gate operator WILL NOT function. s t M Date Installed: Installer/Company Name:...
  • Page 2 QUICK GUIDE: DIP-Switches See page 20 for descriptions about DIP-switches. When a switch setting is changed, power must be turned OFF and then turned back ON for the new setting to take affect. Every time the operator is powered up, the First open command will automatically set the open and close limits of the gate.
  • Page 3 QUICK GUIDE: Terminal Descriptions See page 24 for main terminal wiring. DANGER HIGH VOLTAGE! • When gate is closed, input will open gate. SW 4 • When gate is open and auto close timer 115 VAC - Neutral SW 4, switch 4 is turned ON, input will re-set and hold timer.
  • Page 4 6050 / 6100 SPECIFICATIONS Use this manual for the Model 6050/6100 operators with circuit board 4502-010 Rev AA or higher ONLY. For operators manufactured July 2011 and later. UL325 Class of Operation Model 6050 Class I Only ; Model 6100 Class I, II, III, IV Type of Gate Vehicular Swing Gates Only Inherent Entrapment Protection Device...
  • Page 5: Table Of Contents

    TABLE OF CONTENTS QUICK GUIDE - DIP-SWITCHES and MAIN TERMINAL Quick Guide-1 & 2 Previous Page SPECIFICATIONS ASTM F2200 Standard for Gate Construction Important Safety Instructions Instructions regarding intended installation: Important Notices UL 325 Entrapment Protection Glossary Swing Gate Requirements Swing Gate Protection SECTION 1 - INSTALLATION Operator Position...
  • Page 6: Astm F2200 Standard For Gate Construction

    ASTM F2200 Standard for Gate Construction Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; service@astm.org; or www.astm.org. Important Safety Instructions WARNING - To reduce the risk of injury or death: 1.
  • Page 7: Important Notices

    • For gate operators utilizing contact sensors: 1. One or more contact sensors shall be located where the risk of entrapment or obstruction exist, such as at the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate. 2.
  • Page 8: Ul 325 Entrapment Protection

    UL 325 Entrapment Protection UL 325 Classifications Authoriz ed Personn el ONLY Class I - Residential Class III - Industrial/Limited Access Vehicular Gate Operator Vehicular Gate Operator A vehicular gate operator (or system) intended for use in garages A vehicular gate operator (or system) intended for use in an or parking areas associated with a residence of one-to four single industrial location or building such as a factory or loading dock families.
  • Page 9: Glossary

    Glossary GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area.
  • Page 10: Swing Gate Requirements

    Swing Gate Requirements The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
  • Page 11: Swing Gate Protection

    Swing Gate Protection Non-contact Sensor Minimizes the potential of the gate closing on vehicular or other traffic that loops cannot sense. Monitored device helps protect against Reverse Loop entrapment. Minimizes the potential of the gate closing when a vehicle is present. Warning Signs Number and placement of loops is Permanently mounted...
  • Page 12: Section 1 - Installation

    SECTION 1 - INSTALLATION Prior to beginning the installation of the swing gate operator, we suggest that you become familiar with the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your installation is performed in an efficient and professional manner compliant with UL 325 safety and ASTM F2200 construction standards.
  • Page 13: Post Mount Or Pad Mount Base Assembly

    1.2 Post Mount or Pad Mount Base Assembly (2) 1” bolts through the main gear bracket mounting holes. (2) 1 1/2” bolts through the main gear bracket mounting holes. Post Support Base Screw the posts to the support plate and mount into concrete BEFORE attaching the operator.
  • Page 14: Underground Conduit Requirements

    1.3 Underground Conduit Requirements Primary Secondary Operator Operator Position Position DoorKing’s Primary/Secondary Interconnection Cable (Dual Operator Application Only) (Secondary Operator AC Power and Communication wires) External Safety Devices, Controls and P.A.M.S. Wires (Low Voltage wire insulation) Loop Lead-In Wires (Low Voltage wire insulation) AC Input Power (High Voltage wire insulation) Concrete Pad Sweeps...
  • Page 15: Post Mount

    Note: 2” thick 1.5 Post Mount gate Illustrated. Mount the post base into the concrete 90° before installing the operator. Open Gate The post mount installation will allow the operator to be mounted low enough Concrete 6” 12” to attach the gate bracket to the lower Position gate rail if desired.
  • Page 16: Manually Adjust The Open And Closed Gate Positions

    1.7 Manually Adjust the Open and Closed Gate Positions DO NOT power up the operator to set the open and closed gate positions. The first time the operator is powered up and cycled, it will automatically set the open and close limits. To do this, the arms MUST already be in the correct configuration. Closed Arms Position Open Arms Position Closed Gate...
  • Page 17: Entrapment Protection Installation Required

    1.9 Entrapment Protection Installation REQUIRED A monitored photo sensor (Type B1) or monitored reversing edge (Type B2, see next page) MUST be installed or operator WILL NOT function. Monitored CLOSE Photo Sensor Monitored OPEN Photo Sensor Mounting Position Mounting Position UL sensor mounted just above top of operator 5”...
  • Page 18 1.9 Continued A monitored reversing edge (Type B2) or a monitored photo sensor (Type B1, see previous page) MUST be installed or operator WILL NOT function. Edge Transmitter OPTIONAL wireless transmitter can be used. Monitored Reversing Edge Typical Monitored Reversing Edge mounted on end of gate. Reversing Edge Mointored Sensor Note: Potential...
  • Page 19: Gates Opening Wider Than

    1.10 Gates Opening Wider Than 90° The installation of an operator opening gates wider that 90° is the same for 1.3 through 1.8 except the operator and concrete pad will be in a different position. Individual requirements can be calculated following this 105° demonstrated sample. Gate Bracket Arm Assembly...
  • Page 20: Section 2 - Ac Power To Operator(S)

    SECTION 2 - AC POWER TO OPERATOR(S) Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a licensed electrical contractor perform this work.
  • Page 21: Bi-Parting Gates Wiring - Dual Gate Operators

    2.3 Bi-Parting Gates Wiring - Dual Gate Operators Connect the Primary/Secondary operators together with DoorKing’s interconnection cable as shown (Different lengths sold separately P/N 2600-75x). High voltage power and low voltage communications are supplied to the secondary operator by DoorKing’s UL approved cable Blue that is run in a single conduit.
  • Page 22: Section 3 - Adjustments

    SECTION 3 - ADJUSTMENTS The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then turned back on for the new setting to take effect.
  • Page 23: Dip-Switch Sw 3 & Sw 4 Settings

    3.2 DIP-Switch SW 3 & SW 4 Settings The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then turned back on for the new setting to take affect.
  • Page 24: Dip-Switch Descriptions

    3.3 DIP-Switch Definitions SW 4 (Top 8 Switches) Switches 1-2 These work in conjunction with each other and determine when the relay on the board will be activated. This relay can be used as a switch for various functions such as illuminating a warning light when the gate is moving, or turning on a green light when the gate is full open. This relay is NOT available for these uses if it is being used for the SHADOW loop function.
  • Page 25: Automatic Open / Close Limit Adjustment

    3.4 Automatic Open / Close Limit Adjustment The 6050/6100’s open/close limits DO NOT have to be physically adjusted. The gate open and close positions are determined by the physical stop “Flange” on the elbow assembly (See below). The arms MUST already be in the correct closed configuration (See Section 1.7 on page 11).
  • Page 26: Clutch Adjustment

    3.5 Clutch Adjustment This vehicular gate operator is equipped with an inherent adjustable clutch “Type C” that can be used as an entrapment protec- tion device. If the clutch is intended to be used as such, it must be adjusted to NOT open or close the gate with a sustained force greater than 40 lbs at the leading edge of the gate, except for the first 10 degrees of arc travel after any initiation of movement.
  • Page 27: Section 4 - Wiring

    SECTION 4 - WIRING 4.1 Main Terminal Description DANGER HIGH VOLTAGE! • When gate is closed, input will open gate. SW 4 • When gate is open and auto close timer 115 VAC - Neutral SW 4, switch 4 is turned ON, input will re-set and hold timer.
  • Page 28: Control Wiring

    4.2 Control Wiring Important: Controls intended for user activation must be located at least six (6) feet away from any moving part of the gate and where the Antenna mounted user is prevented from reaching over, outside operator cover. under, around or through the gate to operate the controls.
  • Page 29: Auxiliary Terminal Wiring

    4.3 Auxiliary Terminal Wiring DoorKing Access Control System (Model 1833, 1835, 1837 or 1838) tracker system can be connected. This system can keep track of gate operator cycle count, shorted inputs, loop detector problems, any forced entry attempts, if the 24 VAC Power 24 VAC gate has struck anything during the open or close cycle, power...
  • Page 30: Loop Detector Wiring

    4.4 Loop Detector Wiring • Loop detector wiring is shown for DoorKing plug-in loop detectors. If other loop detectors are used, refer to the installation instructions supplied To help protect the operator from accidentally closing on vehicles with those detectors for wiring instructions. in the gate’s path, DoorKing highly recommends that loops and •...
  • Page 31: Section 5 - Operating Instructions

    SECTION 5 - OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3.
  • Page 32: Shutdown Conditions

    5.2 Shutdown Conditions Under various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. To determine what type of reset action is required, you will need to understand how the different entrapment conditions affect the gate operator.
  • Page 33: Manual Gate Operation

    Resetting a Hard Shutdown When the operator is in a hard shutdown condition (audio alarm activated or audio alarm “chirps” every 5 seconds), the only way to reset the gate operator and return it to normal operation is to activate the alarm reset input (auxiliary terminals 2 and 3).
  • Page 34 FAIL-SAFE Manual Operation The FAIL-SAFE manual operation system is the most reliable and safest method for placing an automated gate in manual operation and is the preferred method of emergency gate operation under worse case conditions by many Fire Chiefs and Building Inspectors and is typically used in CLASS I and CLASS II applications. This system requires no keys, cranks or tools for manual gate operation and is completely automatic.
  • Page 35: Section 6 - Maintenance And Troubleshooting

    SECTION 6 - MAINTENANCE AND TROUBLESHOOTING Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or suspected. High cycle usage may require more frequent service checks. 6.1 Maintenance When servicing the gate operator, always check any (external) safety devices (loops, photo eyes, etc.) for proper operation. If external safety devices cannot be made operable, do not place this operator in service until the malfunction can be identified and corrected.
  • Page 36: Troubleshooting

    6.2 Troubleshooting Have a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of checking up to 500 meg-ohms of resistance is necessary to properly check the integrity of the ground loops. When a malfunction occurs, isolate the problem to one of three areas: 1) the operator, 2) the loop system, 3) the keying devices.
  • Page 37 Symptom Possible Solution(s) • Check that the clutch is adjusted properly and is not slipping. Gate opens a short • Disconnect the gate from the gate operator and check that the gate swings freely without any binding. distance, then stops •...
  • Page 38: Accessory Items

    6.3 Accessory Items UL 325 Monitored Entrapment Protection Devices available for the model 6050 and 6100 swing gate operators. Type B2 Contact Sensors (Reversing Edge) Miller Edge Sensing Edges - all models with a T2 (resistive) termination. Miller Edge Monitored Gate Link Model MGL-K20 Type B1 Non-contact Sensors (Photo Cell) Miller Edge Reflective-Guard Model RG Miller Edge Prime-Guard Model PG...
  • Page 39: Model 6050/6100'S Wiring Diagrams

    Model 6050 / 6100 6050 1/2 HP - 4.3 amp 6050 30uf Capacitor 6100 1/2 HP - 5.4 amp 6100 50uf Capacitor Magnetic Blue Limit Sensor Blue White Ground Ground Board Ground Blue EXIT LOOP Yellow Brown 4502-010 KEY SWITCH DATA POWER SW 4...
  • Page 40 Model 6050 / 6100 Secondary Operator Magnetic Limit Sensor 6050 1/2 HP - 4.3 amp 6100 1/2 HP - 5.4 amp 8. Gray Orange Orange 7. Orange Brown Brown 6. Brown Yellow Yellow 5. Yellow 4. Purple White White 3. White Blue Blue 2.
  • Page 41 6050-065-D-2-16...
  • Page 42: 6050-065

    Installation/Owner’s Manual Series 6050 and 6100 Series 6050 and 6100 Vehicular Swing Gate Operator Use this manual for circuit board 4502-010 Revision K or higher. 6050-065-D-2-16 For operators manufactured July 2011and later. www.doorking.com DoorKing, Inc. 120 S. Glasgow Avenue Inglewood, California 90301 U.S.A.

This manual is also suitable for:

6100 series

Table of Contents