ONLY FOR VEHICULAR TRAFFIC. Pinch Points Pedestrians must be provided with a separate Entrapment access and must stay out of the HAZARD Absence of Controlled Pedestrian Access ZONE. Traffi c Backup HAZARD ZONE 4 installation guide 6002-065-G-08-06...
If any of these functions protection is required, if clearance is more operate improperly, remove the operator from than 16” inches, entrapment protection is not service immediately and contact your service dealer. required. ENTRAPMENT ZONE installation guide 5 6002-065-G-08-06...
Never attempt to manually operate any gate with an operator attached to it until you have verifi ed that power to the operator has been shut-off unless otherwise specifi ed. 8 installation guide 6002-065-G-08-06...
Maximum gate length is 14’ ft. Gate should be mounted on heavy-duty ball bearing hinges. Gate MUST swing freely without binding. installation guide 9 6002-065-G-08-06...
Page 10
GATE OPENS TO THE OUTSIDE GATE OPENS TO THE INSIDE H e a v y - D u t y reinforced bracket extension plate must fabricated when installing the actuator bracket. 10 installation guide 6002-065-G-08-06...
Page 11
Do not cover the holes on the bottom of the motor. Rotate the housing cover to display the DKS logo up-right if required. NOTE: Do not reinstall the actuator cover until the Cover the exposed holes on the top of the actuator with the limits have been adjusted.
It may be necessary to temporarily remove the control box components to avoid any damage when installing. Depending on installation it may be necessary to drill additional mounting holes in the control box. Temporarily cover the terminal strip with tape to avoid damage. 12 installation guide 6002-065-G-08-06...
When installing electrical equipment make certain all wiring complies with local code requirements. Proceed to step 2 if installing a secondary actuator . Components not included, each must be purchased separately. installation guide 13 6002-065-G-08-06...
3000 feet. Use a low voltage surge board other than a low voltage radio suppressor, (DoorKing P/N 1878-010) if low voltage wire runs exceed 1000 feet. All inputs receiver. to the terminal strip must be NORMALLY OPEN. 14 installation guide 6002-065-G-08-06...
Page 15
15. 12 VOLT BATTERY + 16. Not Used 17. ALARM RESET 18. 24V COMMON 19. 24 VAC INPUT 20. 24 VAC INPUT *NOTE: DC power is not present on the board until the fi rst initial cycle. installation guide 15 6002-065-G-08-06...
(Type A) and comes equipped ready to connect a secondary entrapment protection device. Entrapment protection devices are required to reduce the risk of injury. Install sensors where the risk of entrapment or obstruction exists while gate/ barrier is moving. 16 installation guide 6002-065-G-08-06...
Will stop or reverse the close cycle of an automatic gate preventing the gate from closing while a vehicle is exiting or stopped in the gate area. Refer to the separate Loop and Loop Detectors Information Manual (Loop Info G-3-02) when installing loops. installation guide 17 6002-065-G-08-06...
FULL OPEN) and all reversing devices connected to terminal 8 will operate as shadow devices. If this is not desirable, wire the shadow loop detector as instructed above. Refer to the separate Loop and Loop Detectors Information Manual (Loop Info G-3-02) when installing loops. 18 installation guide 6002-065-G-08-06...
Whenever any programming or switch setting on the circuit board is changed, batteries must be disconnected and main power must be shut-off. Once completed turn main power on and re-connect the batteries. The new programming and settings will not take effect unless this procedure is followed. installation guide 19 6002-065-G-08-06...
Relay activated when gate is OPENING or OPEN 1-ON 2-ON Relay activated when gate is OPENING or CLOSING 1 Second Delay to Disengage Mag-Lock DK Gate Deadbolt 4-5 Second Delay to Retract Not Used LEAVE in OFF position 20 installation guide 6002-065-G-08-06...
This feature is especially useful in applications where the gate opens partially, such as on a curved driveway. The actuator must be installed on the gate and power to the circuit board must be ON when adjusting the limit switches. installation guide 21 6002-065-G-08-06...
A good set of roller bearing hinges are essential for proper swing gate operation. Rotating the sensitivity sensor counter-clockwise DECREASES the reverse sensitivity. Rotating the sensitivity sensor clockwise INCREASES the reverse sensitivity. 22 installation guide 6002-065-G-08-06...
Under various entrapment conditions the operator will assume either a soft or hard shutdown (alarm) condition. To determine what type of reset action is required, you will need to understand how the different entrapment conditions affect the gate operator. installation guide 23 6002-065-G-08-06...
High cycle usage may require more frequent service checks (see maintenance schedule). When servicing the gate operator, be sure that the 24 VAC input power, batteries are disconnected. 24 installation guide 6002-065-G-08-06...
Operator is in a “hard shutdown” condition. Reset switch must be be fully charged for proper every 5 seconds. activated to return operator to normal operation, see page 23. operation, replace batteries Operator will not every two years on average. run. installation guide 25 6002-065-G-08-06...
/ accessories The following accessories are available for 6001 / 6002 actuators. Photo Cell: Non-contact (photo-cells) sensors are used as secondary entrapment protection. EMX Industries, Inc., Model IRB-325 MMTC, Inc., Model E3K-R10K4-NR Loop Detector: Detectors plug directly into ports on circuit board.